J. Cardiothorac. Vasc. Anesth. · Jun 1992
Perioperative evaluation of a new mixed venous oxygen saturation catheter in cardiac surgical patients.
- C G Pond, G Blessios, J Bowlin, C McCawley, and D G Lappas.
- Department of Anesthesiology, Washington University School of Medicine, St Louis, MO 63110.
- J. Cardiothorac. Vasc. Anesth. 1992 Jun 1;6(3):280-2.
AbstractFiberoptic pulmonary artery flotation catheters have gained clinical acceptance for continuous monitoring of mixed venous oxygen saturation (SvO2), especially in the management of hemodynamically unstable patients. Therefore, the performance of the oximetry system used is extremely important. The accuracy and stability of a new two-wavelength oximetry pulmonary artery catheter and SAT-2 oximeter were assessed in adult patients during and following cardiac surgery. After in vitro calibration of the system, the catheter was inserted through the right internal jugular vein and positioned in the pulmonary artery prior to induction of anesthesia. During the study period, the system was updated for hemoglobin changes of 1.8 g/dL or more. In vivo SvO2 values obtained by the oximetry catheter were compared with those determined with a reference oximeter from simultaneously drawn mixed venous blood specimens at different intervals. A total of 604 paired data points from 52 patients were analyzed, 572 (94.7%) of which were within the 95% confidence interval. Overall bias was -1.7% +/- 3.5% (SD). The results suggest that over the time course of the study, in vivo SvO2 values obtained with the two-wavelength catheter and the SAT-2 oximeter closely approximated SvO2 measured with a reference oximeter from mixed venous blood samples (r = 0.917; SEE 3.5%) in cardiac surgical patients in whom marked physiological changes occur.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.