-
J Am Soc Echocardiogr · Sep 2002
Correlation between measured inferior vena cava diameter and right atrial pressure depends on the echocardiographic method used in patients who are mechanically ventilated.
- Karim Bendjelid, Jacques-A Romand, Bernhard Walder, Peter M Suter, and Gerard Fournier.
- Surgical Intensive Care Division, Geneva University Hospital, CH-1211 Geneva 14, Switzerland. Karim.Bendjelid@hcuge.ch
- J Am Soc Echocardiogr. 2002 Sep 1;15(9):944-9.
AbstractIn patients who are mechanically ventilated, the correlation between inferior vena cava diameter (IVCD) measurements and mean right atrial pressure (RAP) varies in the literature. The purpose of this study was to test if the correlation between IVCD and RAP measurement in patients who are critically ill depends on the transthoracic echocardiography (TTE) methodology used. Twenty patients who were critically ill, sedated, and required respiratory support were prospectively studied by TTE during mechanical ventilation in a controlled mode. The TTE measures of IVCD were made, using methods previously cited. First, IVCD was measured at end-expiration and end-diastole, with ECG synchronization, using the M-mode, on short-axis view 2 cm below the right atrium. Second, IVCD was assessed at end-expiration, without ECG synchronization, using the 2-dimensional long-axis view at the same location. RAP was measured simultaneously by using a central venous catheter positioned in the superior vena cava. All measurements were taken in the supine position. IVCD at end-expiration and end-diastole, with ECG synchronization, using the M-mode, and IVCD at end-expiration, without ECG synchronization, using the 2-dimensional long-axis view, correlate linearly with RAP (0.81, P <.0001 and 0.71, P =.0004). Mean bias between the 2 TTE methods (Bland-Altman analysis) was 1.6 mm (SD +/- 2.03 mm). In conclusion, this study confirms that variation of correlation between TTE IVCD measurement and RAP depends on the ultrasonographic methodology used and the timing of measurement during the cardiac cycle. IVCD at end-expiration and end-diastole, with ECG synchronization, using the M-mode (IVCD-MM) correlates more satisfactory with RAP than with IVCD at end-expiration, without ECG synchronization, using the 2-dimensional long-axis view, in patients during mechanical ventilation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.