J Vasc Interv Radiol · Apr 2004
Comparative StudyMagnetic resonance imaging characteristics of six radiofrequency electrodes in a phantom study.
- Christophe Aubé, Diethard Schmidt, Jens Brieger, Martin Schenk, Thomas Helmberger, Claudius W Koenig, Fritz Schick, Claus D Claussen, and Philippe L Pereira.
- Department of Radiology, University Hospital of Angers, Angers, France.
- J Vasc Interv Radiol. 2004 Apr 1;15(4):385-92.
PurposeTo evaluate and compare visibility and artifacts in magnetic resonance (MR) compatible radiofrequency (RF) electrodes for MR-guided RF ablation.Material And MethodsSix different MR compatible electrodes for RF ablation including two internally cooled single needles, one internally cooled cluster needle, two expandable needles and one perfused needle were tested in a phantom study at 0.2 Tesla and at 1.5 Tesla field strength. Fluoroscopic, T1- and T2-weighted fast spin echo (FSE) and gradient echo (GE) sequences, which are usually used for MR-guided interventions, were evaluated. Qualitative and quantitative evaluations were performed. Length, width, noise, tip artifacts, global artifacts and global visualization of the RF electrodes that showed all sequences at different angles.ResultsQualitative analysis showed that electrodes were well visualized at all angles and sequences and on both MR imagers. Quantitative analysis showed that artifact-induced widening of the shaft was increased in all electrodes by: a). use of fluoroscopic sequences, GE sequences, and fat saturation, b). increasing the angle between the needle and main magnetic field, and c). high field strength (1.5 T). Expandable needles produced fewer tip artifacts but broader signal voids along the shaft compared to nonexpandable needles. Cluster electrodes produced less widening than the other electrodes.ConclusionVisibility and artifacts in all six MR compatible RF electrodes are satisfactory and these electrodes could be used for MR-guided radiofrequency ablation procedures.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.