• Anesthesia and analgesia · Feb 2013

    Peripheral perfusion index as an early predictor for central hypovolemia in awake healthy volunteers.

    • Michel E van Genderen, Sebastiaan A Bartels, Alexandre Lima, Rick Bezemer, Can Ince, Jan Bakker, and Jasper van Bommel.
    • Department of Intensive Care, Room H-619, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands.
    • Anesth. Analg.. 2013 Feb 1;116(2):351-6.

    BackgroundIn healthy volunteers, we investigated the ability of the pulse oximeter-derived peripheral perfusion index (PPI) to detect progressive reductions in central blood volume.MethodsTwenty-five awake, spontaneously breathing, healthy male volunteers were subjected to progressive reductions in central blood volume by inducing stepwise lower body negative pressure (LBNP) with 20 mm Hg for 5 minutes per step, from 0 to -20, -40, -60, and back to 0 mm Hg. Throughout the procedure, stroke volume (SV), heart rate (HR), and mean arterial blood pressure were recorded using volume-clamp finger plethysmography. Assessment of the PPI was done by pulse oximetry. Additionally, the forearm-to-fingertip skin-temperature gradient was measured. Data are presented as mean±SE. PPI underwent log transformation and is presented as median (25th-75th).ResultsOf the 25 subjects, one did not complete the study because of cardiovascular collapse. After the first LBNP step (-20 mm Hg), PPI decreased from 2.2 (1.6-3.3) to 1.2 (0.8-1.6) (P=0.007) and SV decreased from 116±3.0 mL to 104±2.6 mL (P=0.02). The magnitude of the PPI decrease (41%±6.0%) was statistically different from that observed for SV (9%±1.3%) and HR (3%±1.9%). During progression of LBNP, SV decreased and HR increased progressively with the increased applied negative pressure, whereas the PPI remained low throughout the remainder of the protocol and returned to baseline values when LBNP was released. At -60 mm Hg LBNP, SV decreased and HR increased by 36%±0.9% and 33%±2.4% from baseline, respectively. Mean arterial blood pressure remained in the same range throughout the experiment.ConclusionsThese results indicate that the pulse oximeter-derived PPI may be a valuable adjunct diagnostic tool to detect early clinically significant central hypovolemia, before the onset of cardiovascular decompensation in healthy volunteers.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.