-
- F Dewaele, A F Kalmar, K Van Canneyt, H Vereecke, A Absalom, J Caemaert, M M R F Struys, and D Van Roost.
- Department of Neurosurgery, Ghent University Hospital, Gent, Belgium. frank.dewaele@ugent.be
- Br J Anaesth. 2011 Aug 1;107(2):218-24.
BackgroundSignificant increases in intracranial pressure (ICP) may occur during neuroendoscopic procedures. To detect and prevent serious and sustained increases, ICP should be monitored. At present, controversy exists on the optimal location of the monitoring sensor. Therefore, we conducted an in vitro study to estimate the pressure gradients between the ventricle, the 'gold standard' site, and the rinsing inlet and outlet.MethodsA head model and a standard endoscope were used. Rinsing was enforced by using a pressurized infusion bag. Using clinically relevant flow rates, pressure was measured at the rinsing inlet and outlet, in the ventricle, and at the distal end of the rinsing channel using a tip sensor or a capillary tube.ResultsAt a flow of 61 ml min(-1), the steady-state pressures measured at the rinsing inlet, in the ventricle, and at the rinsing outlet were 38, 26, and 12 mm Hg, respectively. At 135 ml min(-1), these increased to 136, 89, and 42 mm Hg. Transendoscopic pressure measurements were always within 1 mm Hg of the ventricular pressure.ConclusionsDuring endoscopy, measurements at the rinsing inlet overestimated the ventricular pressure by ∼50 mm Hg during heavy rinsing, whereas measurements at the rinsing outlet underestimated the pressure by ∼50 mm Hg. An electronic tip sensor or a pressure capillary tube placed at the distal end of the lumen of the rinsing channel of the endoscope did not interfere with rinsing flow and produced measurements that were equal to ventricular pressures.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.