    Axial characteristics of circular external skeletal fixator single ring constructs.

    • D D Lewis, D G Bronson, A R Cross, R D Welch, and P S Kubilis.
    • Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, FL, USA.
    • Vet Surg. 2001 Jul 1;30(4):386-94.

    ObjectiveEvaluate the effects of varying ring diameter, wire tension, and wire-divergence angle on the axial stiffness characteristics of circular external skeletal fixator single-ring constructs. Study Design-Biomechanical evaluation using circular fixator components and a Delrin cylinder bone model.MethodsSingle ring constructs using two 1.6 mm diameter Kirschner wires to secure a 19 mm Delrin cylinder centered within the ring were examined. Component variables evaluated were ring diameter (50 mm, 66 mm, 84 mm, and 118 mm), wire-divergence angle (30 degrees, 60 degrees, and 90 degrees ), and wire tension (0 kg, 30 kg, 60 kg, and 90 kg). A total of 48 constructs were examined. Rings were rigidly mounted on a universal testing system and the cylinder loaded in axial compression (7.4 N/s) to 220 N. Load/displacement curves were analyzed to determine the following: the displacement (mm) that occurred before the slope of each load/displacement curve became linear, the stiffness (N/mm) of the linear portion of each load/deformation curve, and the total displacement (mm) produced at maximal load. Least-squares linear regression was used to model response variables as linear functions of ring diameter, wire divergence angle, and wire tension. Three-way interactions and 2-way interactions among independent component variables were evaluated first in the modeling process and included in a best model if response variables were found to have statistically significant regression coefficients. The regression coefficients and corresponding standard errors and covariances were used to estimate the maximal effect and standard error attributable to wire divergency angle (change from 30 degrees to 90 degrees ) and wire tension (change from 0 to 90 kg) for each ring diameter.ResultsAll load/deformation curves had an initial exponential increase in stiffness, with the slope becoming linear at higher loads. The exponential phase was more pronounced in larger-diameter ring constructs and was mitigated by tensioning the wires. Ring diameter had the greatest influence on displacement that occurred before the curve became linear (semipartial r(2) [sp-r2] = .89), stiffness (sp-r2 = .94), and total displacement (sp-r2 = .93). Wire tension exerted a smaller influence on displacement that occurred before the curve became linear (sp-r2 =.06), stiffness (sp-r2 = .03), and total displacement (sp-r2 = .05). Wire divergence angle had a nominal effect on displacement that occurred before the curve became linear (sp-r2 = .0001), on stiffness (sp-r2 = .004), and on total displacement (sp-r2 =.003).ConclusionsRing diameter had a profound effect on the axial stiffness characteristic of single ring constructs. Tensioning of the fixation wires can improve the axial stiffness characteristics of these constructs, particularly in larger diameter ring constructs, by mitigating the initial exponential phase of the load/deformation curve. Wire divergence angle had only a nominal differential effect on axial stability.Clinical RelevanceUnderstanding how individual component variables and their interactions influence bone segment stability should help surgeons to optimize interfragmentary strain. Tensioning fixation wires is probably unnecessary in 50 mm diameter ring constructs, but assumes greater importance as ring diameter increases.Copyright 2001 by The American College of Veterinary Surgeons

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…