-
Circ Cardiovasc Interv · Oct 2008
Clinical TrialRetrograde transarterial implantation of a nonmetallic aortic valve prosthesis in high-surgical-risk patients with severe aortic stenosis: a first-in-man feasibility and safety study.
- Joachim Schofer, Michael Schlüter, Hendrik Treede, Olaf W Franzen, Thilo Tübler, Andrea Pascotto, Reginald I Low, Steven F Bolling, Thomas Meinertz, and Hermann Reichenspurner.
- Medical Care Center Prof Mathey, Prof Schofer and Hamburg University Cardiovascular Center, University Heart Center Hamburg, Hamburg, Germany.
- Circ Cardiovasc Interv. 2008 Oct 1;1(2):126-33.
BackgroundTo assess the feasibility and safety of retrograde transarterial implantation of a novel nonmetallic aortic valve prosthesis (Direct Flow Medical Inc, Santa Rosa, Calif), a prospective single-center study was performed in patients with severe aortic stenosis at high risk for open-heart surgery.Methods And ResultsFifteen patients (intention-to-treat cohort) with an aortic valve area < or = 0.8 cm(2), a > or = 35-mm Hg mean transvalvular pressure gradient, and a logistic EuroSCORE > or = 20% were enrolled. Percutaneous aortic valve replacement was performed with the patient under general anesthesia. Hemodynamic parameters were assessed before and after implantation by transesophageal echocardiography. Clinical follow-up and transthoracic echocardiographic assessment were obtained at 30 days. Procedural success was achieved in 12 patients (80%). Surgical conversion became necessary at day 2 in 1 patient; 11 patients (73%) were discharged with a permanent implant. In these patients, implantation resulted acutely in a significant increase in aortic valve area (median, 1.64 [interquartile range, 1.27 to 1.74] versus 0.60 [0.46 to 0.69] cm(2); P = 0.0033) and a concomitant reduction in the mean pressure gradient (14.0 [13.2 to 16.5] versus 54.0 [43.2 to 59.8] mm Hg; P = 0.0033). At 30 days, 1 cardiac death (6.7%; 95% CI, 0.2% to 32.0%) and 1 major stroke were observed. The 10 surviving patients with a permanent implant showed marked hemodynamic and clinical improvement at this time point.ConclusionsIn this small series of patients, percutaneous implantation of the Direct Flow Medical aortic valve prosthesis in high-surgical-risk patients was feasible and associated with a reasonably low safety profile.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.