• Anesthesia and analgesia · Jan 2004

    Randomized Controlled Trial Comparative Study Clinical Trial

    Mechanical versus manual ventilation via a face mask during the induction of anesthesia: a prospective, randomized, crossover study.

    • Achim von Goedecke, Wolfgang G Voelckel, Volker Wenzel, Christoph Hörmann, Horst G Wagner-Berger, Volker Dörges, Karl H Lindner, and Christian Keller.
    • Department of Anesthesiology and Critical Care Medicine, Leopold-Franzens-University, Anichstrasse 35, 6020 Innsbruck, Austria. achim.von-goedecke@uibk.ac.at
    • Anesth. Analg. 2004 Jan 1;98(1):260-3, table of contents.

    UnlabelledOne approach to make ventilation safer in an unprotected airway has been to limit tidal volumes; another one might be to limit peak airway pressure, although it is unknown whether adequate tidal volumes can be delivered. Accordingly, the purpose of this study was to evaluate the quality of automatic pressure-controlled ventilation versus manual circle system face-mask ventilation regarding ventilatory variables in an unprotected airway. We studied 41 adults (ASA status I-II) in a prospective, randomized, crossover design with both devices during the induction of anesthesia. Respiratory variables were measured with a pulmonary monitor (CP-100). Pressure-controlled mask ventilation versus circle system ventilation resulted in lower (mean +/- SD) peak airway pressures (10.6 +/- 1.5 cm H(2)O versus 14.4 +/- 2.4 cm H(2)O; P < 0.001), delta airway pressures (8.5 +/- 1.5 cm H(2)O versus 11.9 +/- 2.3 cm H(2)O; P < 0.001), expiratory tidal volume (650 +/- 100 mL versus 680 +/- 100 mL; P = 0.001), minute ventilation (10.4 +/- 1.8 L/min versus 11.6 +/- 1.8 L/min; P < 0.001), and peak inspiratory flow rates (0.81 +/- 0.06 L/s versus 1.06 +/- 0.26 L/s; P < 0.001) but higher inspiratory time fraction (48% +/- 0.8% versus 33% +/- 7.7%; P < 0.001) and end-tidal carbon dioxide (34 +/- 3 mm Hg versus 33 +/- 4 mm Hg; not significant). We conclude that in this model of apneic patients with an unprotected airway, pressure-controlled ventilation resulted in reduced inspiratory peak flow rates and peak airway pressures when compared with circle system ventilation, thus providing an additional patient safety effect during mask ventilation.ImplicationsIn this model of apneic patients with an unprotected airway, pressure-controlled ventilation resulted in reduced inspiratory peak flow rates and lower peak airway pressures when compared with circle system ventilation, thus providing an additional patient safety effect during face-mask ventilation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…