• Intensive care medicine · Jan 1992

    A fibre optics system for the evaluation of airway pressure in mechanically ventilated patients.

    • R A De Blasi, G Conti, M Antonelli, M Bufi, and A Gasparetto.
    • Istituto di Anestesiologia e Rianimazione, Università La Sapienza, Policlinico Umberto I, Rome, Italy.
    • Intensive Care Med. 1992 Jan 1;18(7):405-9.

    ObjectiveThe present study was intended to evaluate the "in vivo" endotracheal (ET) tube resistance and respiratory mechanics in mechanically ventilated patients with respiratory failure by using fiber optic catheters.DesignTwo fiber optic catheters, consisting of a thin probe with a pressure transducer on the tip, were used. The first was placed at the proximal side of the ET tube and the second was positioned distally beyond the end. A low compliant air-filled catheter connected to a traditional pressure transducer was placed close to the proximal fiber optic device to compare the pressure values obtained with both systems.SettingThe study was performed in the General Intensive Care Unit of Rome "La Sapienza", University Hospital.Patients And ParticipantsSeven patients admitted for the management of acute respiratory failure of different etiologies were included in the protocol. All the patients were intubated and mechanically ventilated for at least 48 h prior to the investigation.Measurements And ResultsThe endotracheal tube resistance was obtained both by the end-inspiratory occlusion method and measuring pressure proximally and distally to the ET tube. The measurement of respiratory mechanics was obtained proximally and distally to the ET tube. Different flows and tidal volume changes were performed. The results showed that the fiber optic device gives an adequate evaluation of airway pressure and the possibility for an easy detection of obstructions and/or deformations of the ET tube. The area described by inspiratory and expiratory pressure recorded at both sides of the ET tube showed a positive relationship between the surface and flows while no surface changes were shown when the tidal volumes were modified. Thoraco-pulmonary compliance measured proximally and distally to the ET tube gave rise to a small and statistically insignificant difference.ConclusionThis study confirms that 48 h after the positioning of ET tubes the airflow resistance is significantly higher than might be expected from the "in vitro" data. The presence of the endotracheal tube can interfere with the evaluation of thoraco-pulmonary mechanics, particularly in dynamic conditions. The fiber optic system represents an interesting and simple tool for the evaluation of ET tube resistance and pulmonary mechanics in patients undergoing mechanical ventilation.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.