• Reg Anesth Pain Med · Nov 2009

    Minimum current requirements for epidural stimulation test confirmation of epidural and intrathecal catheter placement.

    • Michael Alan Sutherland, Christopher M Viscomi, Timothy S Dominick, and Emily L Anderson.
    • Department of Anesthesiology, University of Vermont College of Medicine, Burlington, VT 05408, USA. Michael.Sutherland@vtmednet.org
    • Reg Anesth Pain Med. 2009 Nov 1; 34 (6): 575-7.

    Background And ObjectivesThe typical blind insertion of a catheter into the epidural space risks catheter misplacement into the intrathecal space. The epidural stimulation test is designed to confirm the correct epidural location of a catheter but may also detect unintended intrathecal catheter placement by evaluating the minimum electrical current required for appropriate motor stimulation. Using this test, we observed the minimum current requirements for appropriate motor stimulation of catheters placed in the epidural and intrathecal spaces.MethodsIn this prospective observational study, patients scheduled for epidural catheter placement and intrathecal catheter placement were evaluated by the epidural stimulation test. The epidural space was localized by using a loss-of-resistance technique with normal saline, and the intrathecal space was identified by advancing a Tuohy needle until a continuous flow of clear cerebrospinal fluid was obtained. Afterward, a catheter was placed in the appropriate space, and a nerve stimulator delivered progressively, increasing electrical current until an appropriate muscle contraction was palpated. The minimum milliamperage required for this muscle contraction was our primary outcome measure.ResultsOf 37 catheters intentionally placed in the epidural space, the mean current required to produce an appropriate palpable motor contraction was 7.8 +/- 3.3 mA with a range of 2 to 14 mA. Of the 11 catheters intentionally placed in the intrathecal space, the mean current required to produce an appropriate palpable motor contraction was 1.3 +/- 0.8 mA with a range of 0.05 to 2.4 mA.ConclusionsWe conclude that the epidural stimulation test minimum electrical current requirement seems to be lower for intrathecal compared with epidural catheter placement.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.