• Am J Emerg Med · Jan 2013

    Estimation of central venous pressure using inferior vena caval pressure from a femoral endovascular cooling catheter.

    • Byung Kook Lee, Hyoung Youn Lee, Kyung Woon Jeung, Yong Hun Jung, and Geo Sung Lee.
    • Department of Emergency Medicine, Chonnam National University Hospital, 501757, Gwangju, Republic of Korea.
    • Am J Emerg Med. 2013 Jan 1;31(1):240-3.

    PurposeEndovascular cooling using the femoral cooling catheter is widely practiced. Central venous pressure (CVP) monitoring in patients undergoing femoral endovascular cooling may require the placement of another catheter near the right atrium (RA). We sought to estimate the agreement between the CVP recorded from catheters placed in the superior vena caval pressure (SVCP) and the inferior vena caval pressure (IVCP) recorded from the femoral cooling catheter in patients undergoing femoral endovascular cooling.MethodsWe enrolled adult cardiac arrest survivors undergoing femoral endovascular cooling. A commercially available central venous catheter was placed in the SVC (superior vena cava) near the RA via subclavian venous access. Both SVCP and IVCP were recorded every 4 hours during therapeutic hypothermia. Arterial pressure, heart rate, peak inspiratory pressure (PIP), and positive end expiratory pressure (PEEP) at the time of vena caval pressure measurements were obtained.ResultsA total of 323 pairs of SVCP and IVCP measurements were collected. The correlation coefficient between SVCP and IVCP was 0.965 (P < .001). The mean difference between SVCP and IVCP was -0.45 mm Hg (SD, 1.27; 95% confidence interval, -0.59 to -0.31 mm Hg). The limits of agreement were -2.94 to 2.05 mm Hg. Vena caval pressures were significantly correlated with airway pressures (peak inspiratory pressure and positive end expiratory pressure), whereas the difference between SVCP and IVCP did not correlate with airway pressures.ConclusionInferior vena caval pressure measured via the femoral cooling catheter showed excellent agreement with CVP recorded from catheters placed in the SVC, which indicates that the femoral cooling catheter can be used for monitoring CVP.Copyright © 2013 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…