    The significance of anode location for stimulus-evoked electromyography during iliosacral screw placement.

    • William M Ricci, Anne M Padberg, and Joseph Borrelli.
    • Department of Orthopaedic Surgery, Washington University School of Medicine, One Barnes Hospital Plaza, Suite 11300, St. Louis, MO 63110, USA. ricciw@msnotes.wustl.edu
    • J Orthop Trauma. 2003 Feb 1;17(2):95-9.

    ObjectivesTo determine the effect of anode location on the current threshold required to provoke an electromyograph response during stimulus-evoked electromyography for iliosacral screw placement.DesignProspective cohort.SettingLevel I trauma center.PatientsNineteen consecutive patients with 23 unstable posterior pelvic ring injuries treated with iliosacral screws.InterventionIliosacral screws were inserted percutaneously over guidewires. Twenty-seven screws were inserted, all into the first sacral vertebrae. The guidewire was used as the cathode for constant-current, stimulus-evoked electromyography for all data collection. Stimulus-evoked electromyographs were obtained with the guidewire at four different stations: at the sacroiliac joint (station I), at the first sacral neuroforamen (station II), in the body of the sacrum (station III), and when the iliosacral screw was in final position over the guidewire (station IV).Main Outcome MeasureStimulus-evoked electromyographs were obtained with the anode at four different locations for each of the implant stations. Location A had the anode adjacent to the percutaneous insertion site of the guidewire, location B at the ipsilateral anterior superior iliac spine, location C at the midline, and location D at the contralateral anterior superior iliac spine.ResultsMoving the anode from midline (location C) toward the entry point of the guidewire increased the current threshold required to provoke an EMG response as much as 67.1% (p < 0.05). Moving the anode from midline to the contralateral anterior superior iliac spine decreased thresholds as much as 3.4% (p > 0.05). In one case, anode placement close to the guidewire insertion site (locations A and B) failed to identify a potentially dangerous implant because current thresholds were >8 mA. With the anode at the midline, current thresholds were <8 mA, indicating unsafe guidewire position leading to redirection of the guidewire.ConclusionThe physical location of the anode during stimulus-evoked electromyography monitoring for iliosacral screw placement significantly changes the current thresholds required to provoke an electromyograph response. Current thresholds required to stimulate nerves increase as the anode is moved toward the stimulating electrode. Anode placement ipsilateral to the stimulating electrode may provide a false indication of safe guidewire placement. We recommend anode location at or beyond the midline for stimulus-evoked electromyography monitoring during iliosacral screw placement.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.