-
- Daniel J Burval, Robert F McLain, Ryan Milks, and Serkan Inceoglu.
- Cleveland Clinic Foundation, Cleveland Clinic Spine Institute, Cleveland, OH 44195, USA.
- Spine. 2007 May 1;32(10):1077-83.
Study DesignPedicle screw pullout testing in osteoporotic and control human cadaveric vertebrae, comparing augmented and control vertebrae.ObjectiveTo compare the pullout strengths of pedicle screws fixed in osteoporotic vertebrae using polymethyl methacrylate delivered by 2 augmentation techniques, a standard transpedicular approach and kyphoplasty type approach.Summary Of Background DataPedicle screw instrumentation of the osteoporotic spine carries an increased risk of screw loosening, pullout, and fixation failure. Osteoporosis is often cited as a contraindication for pedicle screw fixation. Augmentation of the vertebral pedicle and body using polymethyl methacrylate may improve fixation strength and construct survival in the osteoporotic vertebrae. While the utility of polymethyl methacrylate has been demonstrated for salvage of screws that have been pulled out, the effect of the cement technique on pullout strength in osteoporotic vertebrae has not been previously studied.MethodsThirteen osteoporotic and 9 healthy human lumbar vertebrae were tested. All specimens were instrumented with pedicle screws using a uniform technique. Osteoporotic pedicles were augmented with polymethyl methacrylate using either a kyphoplasty type technique or a transpedicular augmentation technique. Screws were tested in a paired testing array, randomly assigning the augmentation techniques to opposite sides of each vertebra. Pullout to failure was performed either primarily or after a 5000-cycle tangential fatigue conditioning exposure. After testing, following screw removal, specimens were cut in the axial plane through the center of the vertebral body to inspect the cement distribution.ResultsPedicle screws placed in osteoporotic vertebrae had higher pullout loads when augmented with the kyphoplasty technique compared to transpedicular augmentation (1414 +/- 338 versus 756 +/- 300 N, respectively; P < 0.001). An unpaired t test showed that fatigued pedicle screws in osteoporotic vertebrae augmented by kyphoplasty showed higher pullout resistance than those placed in healthy control vertebrae (P = 0.002). Both kyphoplasty type augmentation (P = 0.007) and transpedicular augmentation (P = 0.02) increased pullout loads compared to pedicle screws placed in nonaugmented osteoporotic vertebrae when tested after fatigue cycling.ConclusionsPedicle screw augmentation with polymethyl methacrylate improves the initial fixation strength and fatigue strength of instrumentation in osteoporotic vertebrae. Pedicle screws augmented using the kyphoplasty technique had significantly greater pullout strength than those augmented with transpedicular augmentation technique and those placed in healthy control vertebrae with no augmentation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.