-
- Marianne J Chapman, Robert J L Fraser, Geoffrey Matthews, Antonietta Russo, Max Bellon, Laura K Besanko, Karen L Jones, Ross Butler, Barry Chatterton, and Michael Horowitz.
- Department of Anaesthesia and Intensive Care, Royal Adelaide Hospital, North Terrace, Adelaide, SA 5000, Australia. marianne.chapman@health.sa.gov.au
- Crit Care. 2009 Jan 1; 13 (4): R140.
IntroductionDelayed gastric emptying occurs frequently in critically ill patients and has the potential to adversely affect both the rate, and extent, of nutrient absorption. However, there is limited information about nutrient absorption in the critically ill, and the relationship between gastric emptying (GE) and absorption has hitherto not been evaluated. The aim of this study was to quantify glucose absorption and the relationships between GE, glucose absorption and glycaemia in critically ill patients.MethodsStudies were performed in nineteen mechanically-ventilated critically ill patients and compared to nineteen healthy subjects. Following 4 hours fasting, 100 ml of Ensure, 2 g 3-O-methyl glucose (3-OMG) and 99mTc sulphur colloid were infused into the stomach over 5 minutes. Glucose absorption (plasma 3-OMG), blood glucose levels and GE (scintigraphy) were measured over four hours. Data are mean +/- SEM. A P-value < 0.05 was considered significant.ResultsAbsorption of 3-OMG was markedly reduced in patients (AUC240: 26.2 +/- 18.4 vs. 66.6 +/- 16.8; P < 0.001; peak: 0.17 +/- 0.12 vs. 0.37 +/- 0.098 mMol/l; P < 0.001; time to peak; 151 +/- 84 vs. 89 +/- 33 minutes; P = 0.007); and both the baseline (8.0 +/- 2.1 vs. 5.6 +/- 0.23 mMol/l; P < 0.001) and peak (10.0 +/- 2.2 vs. 7.7 +/- 0.2 mMol/l; P < 0.001) blood glucose levels were higher in patients; compared to healthy subjects. In patients; 3-OMG absorption was directly related to GE (AUC240; r = -0.77 to -0.87; P < 0.001; peak concentrations; r = -0.75 to -0.81; P = 0.001; time to peak; r = 0.89-0.94; P < 0.001); but when GE was normal (percent retention240 < 10%; n = 9) absorption was still impaired. GE was inversely related to baseline blood glucose, such that elevated levels were associated with slower GE (ret 60, 180 and 240 minutes: r > 0.51; P < 0.05).ConclusionsIn critically ill patients; (i) the rate and extent of glucose absorption are markedly reduced; (ii) GE is a major determinant of the rate of absorption, but does not fully account for the extent of impaired absorption; (iii) blood glucose concentration could be one of a number of factors affecting GE.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.