Multicenter Study Comparative Study Clinical Trial Controlled Clinical Trial
Feasibility of intraperitoneal insulin therapy with programmable implantable pumps in IDDM. A multicenter study. The EVADIAC Study Group. Evaluation dans le Diabète du Traitement par Implants Actifs.
- H Hanaire-Broutin, C Broussolle, N Jeandidier, E Renard, B Guerci, M J Haardt, and V Lassmann-Vague.
- Hôpital Rangueil, Toulouse, France.
- Diabetes Care. 1995 Mar 1;18(3):388-92.
ObjectiveTo report the overall French experience, obtained through the collaboration of seven centers (EVADIAC [Evaluation dans le Diabète du Traitement par Implants Actifs] register), on the safety, feasibility, and efficacy of intraperitoneal insulin therapy by programmable implantable pumps, using three different devices.Research Design And MethodsThis is a multicenter prospective study involving 224 type I diabetic patients implanted with a programmable implantable pump (cumulative follow-up: 353 patient-years; mean duration: 1.5 +/- 0.9 years [mean +/- SD]. The Infusaid and the Promedos devices are equipped with a side port and refilled with U100 insulin (Hoechst 21 PH); the Minimed pump is not equipped with a side port and is refilled with U400 insulin (Hoechst 21 PH). Metabolic data and adverse events were recorded in a central register run by EVADIAC.ResultsA total of 29 local pump-pocket events (8/100 patient-years) and 9 pump failures (2.5/100 patient-years) occurred. The major technical problems were 1) pump flow rate reduction related to insulin aggregates, reversible after alkaline rinsing of the pump, and 2) 47 catheter obstructions requiring laparoscopic or conventional surgery. Pump therapy was abandoned in only 11 patients. HbA1c (7.4 +/- 1.8 vs. 6.8 +/- 1.0%, P < 0.001), mean glycemia (8.7 +/- 1.5 vs. 7.8 +/- 1.0 mmol/l, P < 0.001), and blood glucose SDs (3.8 +/- 0.8 vs. 3.3 +/- 0.8 mol/l, P < 0.001) decreased significantly after 6 months and remained lower than baseline thereafter.ConclusionsIntraperitoneal insulin infusion using an implantable programmable pump is a feasible and relatively safe technique that may improve metabolic control and glycemic stability. Long-term studies, however, are needed to demonstrate whether or not the improvement in glycemic control could be sustained for several years.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.