-
Comparative Study
Comparison of inspiratory and expiratory resistance and reactance in patients with asthma and chronic obstructive pulmonary disease.
- Paolo Paredi, Michael Goldman, Almahdi Alamen, Pilar Ausin, Omar S Usmani, Neil B Pride, and Peter J Barnes.
- Airway Disease Section, National Heart and Lung Institute, Imperial College, Dovehouse Street, London SW3 6LY, UK. p.paredi@imperial.ac.uk
- Thorax. 2010 Mar 1;65(3):263-7.
BackgroundThe usual analysis of forced oscillometry measures respiratory resistance (Rrs) and reactance (Xrs) averaged over several tidal breaths (whole-breath analysis). Recent within-breath analyses have separated Rrs and Xrs into their mean inspiratory and mean expiratory components (inspiratory-expiratory breath analysis) but these have not been used to compare patients with asthma and those with chronic obstructive pulmonary disease (COPD). Large inspiratory-expiratory variations in Xrs at 5 Hz (DeltaX5) in an individual have been used as a surrogate marker of expiratory flow limitation.MethodsWhole-breath and inspiratory-expiratory impulse oscillometry was assessed in 34 patients with asthma (49 + or - 3 years; 15 male, forced expiratory volume in 1 s (FEV(1)) 69 + or - 4% predicted), 48 patients with COPD (64 + or - 2 years; 32 male, FEV(1) 59 + or - 3% predicted) and 18 normal subjects (37 + or - 2 years; 8 male).ResultsWhole-breath analysis failed to discriminate between patients with asthma and patients with COPD either for all patients or for patients with FEV(1) <60% predicted. Inspiratory-expiratory analysis in patients with FEV(1) <60% predicted showed that in the COPD group mean expiratory X5 (-0.44 + or - 0.04 kPa/l/s) was greater than inspiratory X5 (-0.23 + or - 0.02 kPa/l/s, p<0.001) whereas patients with asthma did not show such changes (-0.36 + or - 0.07 kPa/l/s vs -0.26 + or - 0.03 kPa/l/s, p=0.23). Even though DeltaX5 was larger in patients with COPD (0.21 + or - 0.03 kPa/l/s) than in patients with asthma (0.10 + or - 0.07 kPa/l/s), this was not significant (p=0.15).ConclusionsWhole-breath impulse oscillation system analysis failed to discriminate between patients with asthma and those with COPD. Inspiratory-expiratory X5 analysis differentiated patients with asthma from those with COPD presumably reflecting enhanced dynamic airway narrowing on expiration in COPD. Further studies are needed to confirm these differences and investigate their cause.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.