- Christopher T Holley, Bryan A Whitson, Stefan C Bertog, and Rosemary F Kelly.
- University of Minnesota, Department of Surgery, Minneapolis, Minnesota.
- J Card Surg. 2013 Nov 1;28(6):679-82.
AbstractWe report the case of a 61-year-old male with a retained catheter dilator in the right ventricular outflow tract for over 22 years. The management of retained intravascular foreign objects in the myocardium is reviewed.© 2013 Wiley Periodicals, Inc.