• Spine J · Sep 2009

    Revision strategies for single- and two-level total disc arthroplasty procedures: a biomechanical perspective.

    • Bryan W Cunningham, Nianbin Hu, Helen J Beatson, Hassan Serhan, John C Sefter, and Paul C McAfee.
    • Orthopaedic Spinal Research Laboratory, St. Joseph Medical Center, Towson, MD 21204, USA. bcspine@gmail.com
    • Spine J. 2009 Sep 1;9(9):735-43.

    Background ContextThe utilization of motion-preserving implants versus conventional instrumentation systems, which stabilize the operative segments, necessitates improved understanding of their comparative biomechanical properties and optimal biomechanical method for surgical revision.PurposeUsing an in vitro human cadaveric model, the primary objective was to compare the multidirectional flexibility properties of single- versus two-level total disc arthroplasty procedures and determine the acute in vitro biomechanical characteristics of two methods of surgical revision-posterior transpedicular instrumentation alone or circumferential spinal arthrodesis.Study DesignThis in vitro biomechanical study was undertaken to compare the multidirectional flexibility kinematics of single- versus two-level lumbar total disc arthroplasty reconstructions using an in vitro model.MethodsA total of seven human cadaveric lumbosacral spines (L1-sacrum) were biomechanically evaluated under the following L4-L5 reconstruction conditions: intact spine; discectomy alone; Charité total disc replacement; Charité with pedicle screws; two-level Charité (L4-S1); two-level Charité with pedicle screws (L4-S1); Charité L4-L5 with pedicle screws and femoral ring allograft (FRA) (L5-S1); and pedicle screws with FRA (L4-S1). Multidirectional flexibility testing used the Panjabi Hybrid Testing protocol, which includes pure moments for the intact condition with the overall spinal motion replicated under displacement control for subsequent reconstructions. Hence, changes in adjacent level kinematics can be obtained compared with pure moment testing strategies. Unconstrained intact moments of +/-7.5Nm were used for axial rotation, flexion-extension, and lateral bending testing with quantification of the operative- and adjacent-level range of motion (ROM). All data were normalized to the intact spine condition (intact=100%).ResultsIn axial rotation, single- and two-level Charité reconstructions produced significantly more motion than pedicle screw constructs combined with the Charité or FRA (p<.05). There were no differences between the Charité augmented with pedicle screws or pedicle screws with FRA (p>.05). The two-level annulus lumbar resection required for multilevel Charité implantation had an added destabilizing effect, resulting in a 140% to 160% ROM increase over the intact condition. Under two-level reconstructions, rotational motion at the L4-L5 level increased from 160+/-26% to 263+/-65% with the implantation of the second Charité at L5-S1. Flexion-extension and lateral bending conditions with the Charité reconstructions in this group of seven spines demonstrated no significant differences compared with the intact spine (p>.05). The Charité combined with pedicle screws or pedicle screws with FRA significantly reduced motion at the operative level compared with the Charité reconstruction (p<.05). The most pronounced changes in adjacent level kinematics and intradiscal pressures were observed under flexion-extension loading. The addition of pedicle screw fixation increased segmental motion and intradiscal pressures at the proximal and distal adjacent levels compared with the intact and Charité reconstruction groups (p<.05).ConclusionsThe findings highlight a variety of important trends at the operative and adjacent levels. In terms of revision strategies, posterior pedicle screw reconstruction combined with an existing Charité was not found acutely to be statistically different from pedicle screws combined with FRA.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…