-
- M C Plewa, S Sikora, M Engoren, D Tome, J Thomas, and A Deuster.
- St. Vincent Medical Center, Toledo, OH 43608-2691, USA.
- Acad Emerg Med. 1995 Oct 1; 2 (10): 901-8.
ObjectiveTo evaluate the ability of noninvasive capnographic measurement of end-tidal CO2 tension (PetCO2) to predict arterial CO2 tension (PaCO2) in nonintubated ED patients with respiratory distress.MethodsA prospective, nonblind study was performed in a level I trauma center/community teaching hospital ED. Participants included all nonintubated adult patients with respiratory distress requiring measurement of arterial blood gases (ABGs); 29 patients were enrolled. PetCO2 was measured with a capnography monitor, using both baseline tidal volumes and forced expiratory volumes. The bias between PetCO2 values and simultaneous measurements of PaCO2 by ABG was assessed.ResultsPetCO2, measured with forced expiration, and PaCO2 agreed well, with bias (i.e., average difference) = 0.44 +/- 0.52 kPa (3.3 +/- 3.9 torr). PetCO2 measured with the tidal volume breath produced an unacceptably high bias of 0.82 +/- 0.70 kPa (6.1 +/- 5.2 torr). Levels of agreement between PaCO2 were similar for smokers and nonsmokers and for men and women. The arterial-end-tidal CO2 tension (Pa-etCO2) difference was not related to PaCO2. Pa-etCO2 correlated with age (r = 0.473; p = 0.01), and was significantly higher in patients with pulmonary disease (1.32 +/- 0.56 kPa; 9.9 +/- 4.2 torr) than it was in those without pulmonary disease (0.46 +/- 0.55 kPa; 3.5 +/- 4.1 torr; p < 0.001).ConclusionsNoninvasive PetCO2 monitoring may adequately predict PaCO2 in nonintubated ED patients with respiratory distress who are able to produce a forced expiration. PetCO2 is less accurate for PaCO2 with tidal volume breathing and in patients with pulmonary disease.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.