• Chest · Dec 2004

    Comparative Study

    Lack of equivalence between central and mixed venous oxygen saturation.

    • Lakhmir S Chawla, Hasan Zia, Guillermo Gutierrez, Nevin M Katz, Michael G Seneff, and Muhammed Shah.
    • The George Washington University MFA, 2150 Pennsylvania Ave NW, Suite 5-404, Washington, DC 20037, USA.
    • Chest. 2004 Dec 1;126(6):1891-6.

    Study ObjectiveWe compared paired samples of central venous O(2) saturation (Scvo(2)) and mixed venous O(2) saturation (Svo(2)) to test the hypothesis that Scvo(2) is equivalent to Svo(2). We also compared O(2) consumption (Vo(2)) computed with Scvo(2) (Vo(2)cv) to that computed with Svo(2) (Vo(2)v).DesignProspective, sequential, observational study.SettingCombined medical-surgical ICU.PatientsFifty-three individuals > 18 years of age of either sex who required a pulmonary artery catheter (PAC) to guide fluid therapy. Subjects were identified as postsurgical (32 patients) or medical (21 patients) according to their ICU admission diagnosis.InterventionsA PAC was inserted through the internal jugular or subclavian veins. Care was taken to place the PAC proximal port approximately 3 cm above the tricuspid valve. Blood samples were drawn from the proximal and distal ports in random order. An arterial blood sample also was drawn.MeasurementsCardiac output in triplicate, systemic pressure, and central pressure. We analyzed blood samples for hemoglobin concentration and O(2) saturation (So(2)). Data were compared by correlation analysis and by the method of Bland and Altman.ResultsSvo(2) was consistently lower than Scvo(2) (p < 0.0001), with a mean (+/-SD) bias of -5.2 +/- 5.1%. Similar differences in Scvo(2) and Svo(2) were present within each subgroup (p < 0.001). A lower Svo(2) resulted in Vo(2)v values that were higher than the Vo(2)cv values for all patients in the study (mean Vo(2)v, 236.7 +/- 103.4 mL/min; mean Vo(2)cv, 191.1 +/- 84.0 mL/min; p < 0.001) as well as for patients within each subgroup (p < 0.001).ConclusionsMeasurements of Scvo(2) and Svo(2) were not equivalent in this sample of critically ill patients. Moreover, substituting Scvo(2) for Svo(2) in the calculation of Vo(2) produced unacceptably large errors. The decrease in So(2) between Scvo(2) to Svo(2) may result from the mixing of atrial and coronary sinus blood. As such, this difference may be a marker of myocardial O(2) consumption.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…