Intraobserver and interobserver reproducibility in the evaluation of optic disc stereometric parameters by Heidelberg Retina Tomograph.
- Stefano Miglior, Elena Albé, Magda Guareschi, Luca Rossetti, and Nicola Orzalesi.
- Dipartimento di Neuroscienze e Tecnologie Biomediche, Universitá degli Studi di Milano Bicocca, Milan, Italy.
- Ophthalmology. 2002 Jun 1;109(6):1072-7.
PurposeTo assess intraobserver and interobserver reproducibility of the measurement of stereometric parameters of the optic disc by means of the Heidelberg Retina Tomograph I (HRT).Study DesignObservational study, with interobserver variability.ParticipantsFifty-five volunteers (healthy subjects and patients with glaucoma).MethodsHRT examination of the optic disc was repeated on 3 consecutive days on 1 eye of each of the 55 subjects. During each session, five single images were randomly acquired by two independent observers. One mean topography image (MTI), based on three single images, was then built at each session. For the intraobserver intraimage evaluation, the two observers traced their own contour line on one randomly chosen MTI. This procedure was repeated three times. For the intraobserver interimage and interobserver intra/interimage evaluations, the two observers traced their own contour line on the MTI of the first session, which was then automatically superimposed on the MTIs of the other two sessions.Main Outcome MeasuresReproducibility of the 12 stereometric parameters was calculated for each observer by means of the intraclass correlation coefficient (ICC). The expected range of variability between two independent evaluations was calculated by the scatter-plots of each test-retest difference versus their mean. The standard deviation of the mean test-retest score differences was used to describe the spread of score differences.ResultsThe ICC ranged between 0.79 and 0.99 for intraobserver intraimage and between 0.56 and 1 for intraobserver interimage evaluation. The ICC ranged between 0.54 and 0.99 for interobserver intraimage and between 0.65 and 0.97 for the interobserver interimage evaluation. ICC was almost perfect to perfect for planimetric measures (0.81 < ICC < or = 1), substantial to almost perfect for volumetric and cup measures (0.61 < ICC < or = 0.99), and moderate to almost perfect for retinal nerve fiber layer related measures (0.41 < ICC < 0.99). The expected variability was low (95% confidence interval, < +/-9%). Interimage evaluation showed a higher variability than intraimage evaluation in both of interobserver (P = 0.012) and intraobserver evaluation (P = 0.028 and P = 0.031 for the two observers).ConclusionsMeasurement of optic disc stereometric parameters by HRT is highly reproducible. However, the use of retinal nerve fiber layer-related parameters should be taken cautiously. The image acquisition-induced variability seems larger than the operator-induced variability.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.