Anesthesia and analgesia · Jun 2011
Suppression of cautery-induced electromagnetic interference of cardiac implantable electrical devices by closely spaced bipolar sensing.
- Mithun Suresh, David G Benditt, Barbara Gold, Girish P Joshi, and Keith G Lurie.
- Department of Medicine, University of Minnesota Medical School, Minneapolis, MN 55455, USA.
- Anesth. Analg. 2011 Jun 1;112(6):1358-61.
BackgroundElectromagnetic interference (EMI) induced by electrocautery during surgery in patients with cardiac pacemakers or implanted cardioverter-defibrillators (ICDs) may inhibit pacing and cause inappropriate tachyarrhythmia oversensing. In particular, susceptibility to EMI may be enhanced in ICDs by frequently used wide interelectrode sensing (i.e., integrated bipolar sensing). Consequently, ICD function is usually disabled preoperatively and restored later by noninvasive programming. Because sensing by closely spaced electrodes (i.e., true bipolar) may be less susceptible to EMI, preoperative programming to a true bipolar mode may minimize the need for perioperative programming while preserving device function.MethodsOur study population consisted of 23 consecutive patients either receiving a new ICD or undergoing ICD pulse generator change. In each patient, electrocautery-induced EMI was initiated with the ICD in the closely spaced sensing configuration and again during widely spaced sensing.ResultsIn comparing the 2 sensing modes, right ventricular electrogram amplitude was significantly greater and EMI noise amplitude tended to be greater with widely spaced bipolar sensing. Furthermore, widely spaced bipolar sensing was associated with ICD pacing inhibition in 22 of 23 patients and incorrect "ventricular fibrillation" detection in 17 of 23 patients. Conversely, closely spaced bipolar sensing was not accompanied by either pacing inhibition or incorrect ventricular fibrillation sensing.ConclusionClosely spaced bipolar sensing (i.e., true bipolar) appropriately rejects electrocautery-induced EMI. Programming implanted devices to closely spaced bipolar sensing may minimize the need for perioperative reprogramming while preserving intraoperative device operation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.