-
J. Am. Coll. Cardiol. · Oct 1993
Unique sensing errors in third-generation implantable cardioverter-defibrillators.
- D J Callans, B G Hook, R B Kleiman, R L Mitra, B T Flores, and F E Marchlinski.
- Clinical Electrophysiology Laboratory, Hospital of the University of Pennsylvania, Philadelphia.
- J. Am. Coll. Cardiol. 1993 Oct 1;22(4):1135-40.
ObjectivesThird-generation cardioverter-defibrillators appear to be susceptible to unique sensing errors. This study was performed to determine the incidence and types of sensing errors in combination therapy implantable devices.BackgroundOne of the advantages offered by third-generation implantable cardioverter-defibrillators is the combination of bradycardia and antitachycardia pacing and cardioversion-defibrillation capabilities in a single device. The potential for unique sensing errors, those caused by the conflicts presented by combining bradycardia and tachycardia sensing and therapy algorithms in the same device, has not been previously addressed.MethodsTo determine the incidence of important sensing errors, 61 patients with a combination therapy device (Cadence [Ventritex] and PCD [Medtronic]) were studied for a 25-month period. In addition to surface electrocardiographic recordings during implantation and routine device testing, real-time and stored electrograms recorded from the rate-sensing leads (Cadence) and real-time marker channel recordings (PCD) were reviewed to diagnose sensing errors that resulted in symptoms, device inefficacy or delivery of inappropriate therapy. After recognition, specific reprogramming steps were performed in an attempt to avoid recurrent sensing errors.ResultsA total of 13 sensing errors were diagnosed in 12 patients (19.7%); the incidence was similar in both devices. Five distinct categories of sensing errors were identified. After device reprogramming, only one recurrent error occurred in 98 patient-months of follow-up.ConclusionsImportant sensing errors occur in approximately 20% of patients with third-generation combination therapy cardioverter-defibrillators. Prompt diagnosis of sensing errors can lead to specific reprogramming steps to avoid recurrent errors.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.