• Int J Artif Organs · May 2010

    Adaptive support ventilation: a translational study evaluating the size of delivered tidal volumes.

    • Denise P Veelo, Dave A Dongelmans, Jan M Binnekade, Frederique Paulus, and Marcus J Schultz.
    • Department of Intensive Care Medicine, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
    • Int J Artif Organs. 2010 May 1;33(5):302-9.

    PurposeAdaptive support ventilation (ASV) is a microprocessor-controlled, closed-loop mode of mechanical ventilation that adapts respiratory rates and tidal volumes (V(T)s) based on the Otis least work of breathing formula. We studied calculated V(T)s in a computer simulation model, and V(T)s delivered in a test lung setting as well as in clinical practice.Materials And MethodsIn a computer simulation model using the Otis formula, V(T)s were calculated for increasing predicted body weights (from 50 to 80 kg) and increasing minute volumes (from 0.7 to 1.5 ml/kg). Different compliance-resistance combinations were chosen to mimic "acute lung injury (ALI)" (compliance 27 ml/cmH(2)O, resistance 20 cmH(2)0 l/s), "ALI using an open lung approach" (compliance 50 ml/cmH(2)O, resistance 20 cmH(2)0 l/s), "healthy lungs" (compliance 65 ml/cmH(2)O, resistance 20 cmH(2)0 l/s) and "chronic obstructive pulmonary disease (COPD)" (compliance 80 ml/cmH(2)O, resistance 50 cmH(2)O l/s). In a test setting using a human ventilator connected to a test lung set to mimic similar pulmonary conditions, V(T)s delivered by the ASV were studied. In a series of stable intensive care unit patients after cardiothoracic surgery, the delivered V(T)s were collected and analyzed.ResultsV(T)s with the Otis formula resembled those in the test setting. With ALI, the ventilator delivered V(T)s between 6 and 8 ml/kg. With ALI using an open lung approach and with healthy lungs, the ventilator delivered V(T)s between 8 and 10 ml/kg. With COPD, all V(T)s were above 10 ml/kg. In patients after coronary artery bypass surgery ASV delivered V(T)s between 7 and 9 ml/kg and V(T)s never exceeded 10 ml/kg.DiscussionThe ASV performed as intended, bearing in mind that the ASV algorithm was originally designed to provide V(T)s between 8 and 12 ml/kg. However, the V(T)s that were calculated and delivered were frequently higher than those presently recommended in the guidelines. Considering the size of V(T) delivered in the setting of ALI using an open lung approach as well as in the setting of COPD, we feel caution should be taken when applying ASV in patients with these conditions.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…