- Goverdhan D Puri, Aveek Jayant, Morup Tsering, Motup Dorje, and Motup Tashi.
- Department of Anaesthesia and Intensive Care, Post Graduate Institute of Medical Education and Research, Chandigarh, Punjab, India.
- Indian J Anaesth. 2012 May 1;56(3):238-42.
BackgroundClosed loop anaesthesia delivery systems (CLADSs) are a recent advancement in accurate titration of anaesthetic drugs. They have been shown to be superior in maintaining adequate depth of anaesthesia with few fluctuations as compared with target-controlled infusion or manual titration of drug delivery.MethodsTwenty patients scheduled to undergo general abdominal or orthopaedic procedures under general anaesthesia at Leh (3505 m above sea level) were recruited as subjects. Anaesthesia was delivered by a patented closed loop system that uses the Bispectral Index (BIS™) as a feedback parameter to titrate the rate of propofol infusion. All vital parameters, drug infusion rate and the BIS™ values were continuously recorded and stored online by the system. The data generated was analysed for the adequacy of anaesthetic depth, haemodynamic stability and post-operative recovery parameters.ResultsThe CLADS was able to maintain a BIS™ within ±10 of the target of 50 for 85.0±7.8% of the time. Haemodynamics were appropriately maintained (heart rate and mean arterial blood pressure were within 25% of baseline values for 91.2±2.2% and 94.1±3% of the total anaesthesia time, respectively). Subjects were awake within a median of 3 min from cessation of drug infusion and achieved fitness to recovery room discharge within a median of 15 min. There were no adverse events or report of awareness under anaesthesia.ConclusionsThe study demonstrates the safety of our CLADS at high altitude. It seeks to extend the use of our system in challenging anaesthesia environments. The system performance was also adequate and no adverse events were recorded.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.