Case Reports
Emergency placement of a self-expandable covered stent for carotid artery injury during trans-sphenoidal surgery.
- Gilberto Ka Kit Leung, Kai Ming Auyeung, Wai Man Lui, and Yiu Wah Fan.
- Division of Neurosurgery, Department of Surgery, Queen Mary Hospital, Hong Kong, SAR, China. gilbertleung2002@yahoo.com
- Br J Neurosurg. 2006 Feb 1;20(1):55-7.
AbstractA patient sustained internal carotid artery (ICA) injury during trans-sphenoidal surgery. Bleeding from the resultant pseudo-aneurysm was not fully controlled by surgical packing. Emergency endovascular deployment over the injured ICA segment of a self-expandable covered-stent ('Symbiot' stent), initially designed for use in coronary saphenous vein-graft, was successful in securing haemostasis.