• Pacing Clin Electrophysiol · Aug 1993

    Feasibility of measuring relative right ventricular volumes and ejection fraction with implantable rhythm control devices.

    • R Chirife, D F Ortega, and A I Salazar.
    • Institute of Cardiology, National Academy of Medicine, Buenos Aires, Argentina.
    • Pacing Clin Electrophysiol. 1993 Aug 1;16(8):1673-83.

    AbstractEjection fraction (EF), the ratio between stroke volume (SV) and end-diastolic volume (EDV), is a valuable contractility indicator. Unlike SV, the Frank-Starling effect is automatically compensated in the calculation of EF. It was the aim of this study to evaluate the physiological behavior of impedance derived measurements of relative right ventricular (RV) volumes and EF, obtained with standard pacing leads. Seven patients were evaluated at the time of pacemaker implant or replacement. Since no absolute standard of comparison was available for RV volumes, the value of the measurements was assessed by observing their behavior under cardio-circulatory challenges. A 2.5-kHz carrier was fed to the ring and tip electrodes of standard bipolar pacing leads and the resulting voltage was digitized and stored. The peak-to-peak voltage (PPV) of the carrier at the time of QRS was used as EDV, and the largest PPV as end-systolic volume (ESV). Relative SV was the difference between EDV and ESV, and EF = SV/EDV x 100. Pacing was used to reduce EDV, and the effect of contractility was tested with isometric hand grip, recumbent leg exercise, or isoproterenol drip. Only minimal changes in EF were noted during incremental pacing; relative SV and EDV decreased as expected; and EF increased significantly during contractility challenges. A high correlation coefficient was observed between EDV and SV changes induced by incremental pacing at rest (r values from 0.62 to 0.98, P from < 0.01 to 0.001). The study revealed that impedance volumetry, utilizing conventional bipolar pacing leads, yields useful hemodynamic data related to EDV, ESV, and EF. Given the simplicity of the method, it is reasonable to conclude on the feasibility of using said impedance derived hemodynamic parameters in implantable rhythm control devices.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.