• Zhonghua yi xue za zhi · Jan 2009

    Comparative Study

    [Development of static three dimensional screw-plate system and the biomechanic features thereof, a comparative study].

    • Jie-Yu Liang, Kang-Hua Li, Qian-De Liao, Yong Zhu, Yi-He Hu, and Guang-Hua Lei.
    • Department of Orthopedics, Xiangya Hospital, Central-South University, Changsha 410008, China.
    • Zhonghua Yi Xue Za Zhi. 2009 Jan 6;89(1):12-6.

    ObjectiveTo develop a new internal fixation device and the matching tools for subtrochanteric fracture, investigate the biomechanical features thereof, and compare its effects with those of other instruments.MethodsA new internal fixation device, static three dimensional screw-plate system: (STDSP) was developed based on the anatomical parameters and the biomechanical characteristics of proximal femur and combined with the biomechanical advantages of the model of three-dimensional plate and multiple-screws plate fixation. Sixteen paired cadaveric adult femurs were randomly divided into 2 equal groups: fracture healing group undergoing insertion of implant and then taking out thereof with a nail left, and fracture group with a trapezoid defect to mimic subtrochanteric fracture 4 of which were fixed with dynamic hip screw (DHS) and STDSP or Gamma nail and STDSP. All the specimens underwent A-P position four point bending test, axial compression test, torsion test, and destroyable test.Results(1) In the fracture group, A-P position four point bending test showed that the stretch displacement of STDSP group was (0.221 +/- 0.089) mm, significantly smaller than that of the Gamma nails group [(0.506 +/- 0.086) mm, t = 38.278 P = 0.000]; Axial compression test showed that the inferior displacement of the STDSP group was (2.804 +/- 0.585) mm, significantly larger than that of the Gamma nail group [(1.874 +/- 0.549) mm, t = -5.454, P = 0.012]; Torsion test showed that the torque values at 50 and 100 of the STDSP group were (3.78 +/- 0.84) J and (2.3 +/- 1.08) J, both significantly larger than those of the Gamma nail groups [(2.3 +/- 1.08) J and (4.35 +/- 1.81) J, t = -4.729 P = 0.018, and t = -3.227 P = 0.048] and those of the DHS group [(7.3 +/- 1.273) J and (4.325 +/- 0.88) J respectively, t = -3.242 P = 0.048]; and torsion destroyable test showed that the torque values at 200 of the STDSP group was (21.88 +/- 2.51) J, significantly larger than those of the Gamma nail and DHS groups, [(14.36 +/- 5.01) J and (15.475 +/- 1.924) J and (12.075 +/- 1.179) J, t = -3.323 P = 0.048, t = - 3.732 P = 0.034]. (2) In the fracture healing specimens, A-P position four point bending test showed that the radial degree displacement of the STDSP group was (1. 050 +/- 0.316) mm, significantly smaller than that of the DHS group [(1.261 +/- 0.364) mm, t = 3.4 P = 0.042].ConclusionsMore capable of resisting bending than DHS and less capable of resisting axial compression, STDSP is an excellent internal fixator with good biomechanical feature in treating subtrochanteric femoral fracture.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.