• IEEE Trans Biomed Eng · Jan 2012

    An algorithm used for ventricular fibrillation detection without interrupting chest compression.

    • Yongqin Li, Joe Bisera, Max Harry Weil, and Wanchun Tang.
    • Weil Institute of Critical Care Medicine, Rancho Mirage, CA 92270, USA. leeoken@gmail.com
    • IEEE Trans Biomed Eng. 2012 Jan 1;59(1):78-86.

    AbstractVentricular fibrillation (VF) is the primary arrhythmic event in the majority of patients suffering from sudden cardiac arrest. Attention has been focused on this particular rhythm since it is recognized that prompt therapy, especially electrical defibrillation, may lead to a successful outcome. However, current versions of automated external defibrillators (AEDs) mandate repetitive interruptions of chest compression for rhythm analyses since artifacts produced by chest compression during cardiopulmonary resuscitation (CPR) preclude reliable electrocardiographic (ECG) rhythm analysis. Yet, repetitive interruptions in chest compression are detrimental to the success of defibrillation. The capability for rhythm analysis without requiring "hands-off" intervals will allow for more effective resuscitation. In this paper, a novel continuous-wavelet-transformation-based morphology consistency evaluation algorithm was developed for the detection of disorganized VF from organized sinus rhythm (SR) without interrupting the ongoing chest compression. The performance of this method was evaluated on both uncorrupted and corrupted ECG signals recorded from AEDs obtained from out-of-hospital victims of cardiac arrest. A total of 232 patients and 31,092 episodes of either VF or SR were accessed, in which 8195 episodes were corrupted by artifacts produced by chest compressions. We also compared the performance of this method with three other established algorithms, including VF filter, spectrum analysis, and complexity measurement. Even though there was a modest decrease in specificity and accuracy when chest compression artifact was present, the performance of this method was still superior to other reported methods for VF detection during uninterrupted CPR.© 2011 IEEE

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…