-
J Bone Joint Surg Am · May 2008
Biomechanical evaluation of periprosthetic femoral fracture fixation.
- Rad Zdero, Richard Walker, James P Waddell, and Emil H Schemitsch.
- Martin Orthopaedic Biomechanics Laboratory, Shuter Wing (Room 5-066), St. Michael's Hospital, 30 Bond Street, Toronto, ON L5G-456, Canada.
- J Bone Joint Surg Am. 2008 May 1;90(5):1068-77.
BackgroundA variety of methods are available for the fixation of femoral shaft fractures after total hip arthroplasty. However, few studies in the literature have quantified the performance of such repair constructs. The aim of this study was to evaluate biomechanically four different constructs for the fixation of periprosthetic femoral shaft fractures following total hip arthroplasty.MethodsTwenty synthetic femora were tested in axial compression, lateral bending, and torsion to determine initial stiffness, as well as stiffness following fixation of a simulated femoral midshaft fracture with and without a bone gap. Four fracture fixation constructs (five specimens per group) were assessed: construct A was a Synthes locked plate (a twelve-hole broad dynamic compression plate) with locked screws; construct B, a Synthes locked plate (a twelve-hole broad dynamic compression plate) with cables and locked screws; construct C, a Zimmer nonlocking (eight-hole) cable plate with cables and nonlocked screws; and construct D, a Zimmer nonlocking (eight-hole) cable plate with allograft strut, cables, and nonlocked screws. Axial stiffness, lateral bending stiffness, and torsional stiffness were assessed with respect to baseline intact specimen values. Axial load to failure was also measured for the specimens.ResultsConstruct D demonstrated either equivalent or superior stiffness in all testing modes compared with the other constructs in femora with both a midshaft fracture and a bone gap. A comparison of constructs A, B, and C demonstrated equivalent stiffness in all test modes (with one exception) in femora with a midshaft fracture and a bone gap.ConclusionsA combination of a nonlocking plate with an allograft strut (construct D) resulted in the highest stiffness of the constructs examined for treating a periprosthetic fracture around a stable femoral component of a total hip replacement.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.