• Resuscitation · Feb 2003

    Randomized Controlled Trial Comparative Study Clinical Trial

    Evaluation of a defibrillator-basic cardiopulmonary resuscitation programme for non medical personnel.

    • Lars Wik, Elizabeth Dorph, Bjørn Auestad, and Andreas Steen Petter P.
    • Department of Emergency Medical Services, Division of Surgery, Ulleval University Hospital, N-0407 Oslo, Norway. lars@nakos.org
    • Resuscitation. 2003 Feb 1; 56 (2): 167-72.

    AbstractTo improve the outcome for out-of-hospital patients with ventricular fibrillation/pulseless ventricular tachycardia (VF/VT), the use of automated external defibrillators (AEDs) by first responders including non-medical personnel with a duty to respond to an emergency is recommended. A special CPR-AED course has been developed. We wanted to test the results (quality and speed of operating an AED and CPR) after completion of such a course and retention after approximately 1-year. At the same time we wanted to see if personnel could use an AED after receiving written information without having attended the course. Study subjects were divided randomly into groups, and tested pre-course (n=54), post-course (n=50), and unannounced 10+/-3 months after the course (retention group, n=61). For statistical analysis two sample tests for binomial proportions and Wilcoxon-Mann-Whitney test was used as appropriate. Fifteen of the 27 pairs (56%) in the pre-course group with no previous exposure to an AED decided to use it. There was no difference between the groups in electrode pad positioning, and all stayed clear of the manikin during the process of AED charging and shock delivery. The post-course group had a higher rate of checking for responsiveness (vs. pre-course), not to check for a pulse (vs. both other groups), the shortest time interval from arrival on scene to start of CPR and shock delivery, and in parallel the shortest hands-off interval (without chest compressions and ventilations) before shock delivery. The quality of chest compressions was improved by the course but decreased to a similar standard as in the pre-course when tested 10+/-3 months later, except for correct depth which was similar to post course. Most ventilation attempts in all groups were scored as incorrect due to the high incidence of excessively rapid inflations. The retention group had a lower frequency of correct inflations than the pre-course group, and the post-course group the highest number of correct ventilations per minute. These findings suggest that use of an AED by untrained laypersons may be feasible and that complex and time-consuming training programmes may not be necessary. The present study also supports the need for annual training and recertification.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…