• J Am Soc Echocardiogr · May 2003

    Correlation of the Tei index with invasive measurements of ventricular function in a porcine model.

    • Jared C LaCorte, Santos E Cabreriza, David G Rabkin, Beth F Printz, Lindita Coku, Alan Weinberg, Welton M Gersony, and Henry M Spotnitz.
    • Division of Pediatric Cardiology, Children's Hospital of New York Presbyterian, NY, USA.
    • J Am Soc Echocardiogr. 2003 May 1;16(5):442-7.

    BackgroundThe Doppler myocardial performance (Tei) index has been reported to be clinically useful in assessing left ventricular systolic and diastolic function in both adults and children. However, there are limited data to compare the Tei index with invasive measurements of ventricular function. We used a porcine model to directly correlate the Tei index with invasive indices of systolic and diastolic function.MethodsPressure volume loops were obtained from 10 pigs (32-45 kg). A micromanometer and a conductance catheter were placed in the left ventricle to record pressure and volume, respectively. A flow probe was placed around the ascending aorta to record cardiac output. Baseline pressure volume loops were generated during preload reduction through caval occlusion. Epicardial echocardiograms were performed just before the caval occlusion. Invasive indices including preload recruitable stroke work, ventricular stiffness constant, and cardiac output were assessed, as were noninvasive echocardiographic indices including Tei index and ejection fraction. An ischemic insult, ventricular fibrillation, was induced to alter ventricular function. After cardioversion and 40 minutes of reperfusion, echocardiographic and invasive measurements were repeated.ResultsThere was a statistically significant inverse relationship between the percent change in Tei and the percent change in preload recruitable stroke work after ventricular fibrillation (r = -0.70, P =.02), although the correlation between the actual values of Tei and preload recruitable stroke work were not statistically significant. There was a statistically significant inverse relationship between the percent change in Tei and the percent change in cardiac output (r = -0.65, P =.03). There was a direct correlation between the value of Tei and the ventricular stiffness constant at baseline (r = 0.63, P <.05). As anticipated, the value of Tei was inversely related to ejection fraction by epicardial echocardiogram at baseline (r = -0.85, P <.001). The percent change in Tei was inversely related to the percent change in ejection fraction as well (r = -0.69, P <.05).ConclusionsThis animal model is one of the first studies to demonstrate a direct correlation between the Tei index and systolic and diastolic invasive measurements of ventricular function. This supports the clinical use of this index as a measure of global ventricular function.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…