- Jeyakumar Ratnam Apollos, Matthew Lawrence, and Rachel Victoria Guest.
- Departments of Surgery.
- JSLS. 2015 Apr 1;19(2).
Background And ObjectivesLoss of visualization of the surgical field due to pneumoperitoneum deflation when CO2 insufflator cylinders become empty can occur at key moments during laparoscopic surgery. The purpose of this study was to examine the incidence of intraoperative cylinder exhaustion in the United Kingdom, determine its impact on patient safety, and design and test a novel device to minimize the phenomenon.MethodsWe performed a national cross-sectional survey of U.K. surgeons, inviting all members of the Association of Surgeons of Great Britain and Ireland (ASGBI) and the Association of Upper GI Surgeons (AUGIS) to participate. We designed and tested a novel dual-valve system to allow rapid intraoperative exchange of CO2 cylinders.ResultsEighty-five percent of the U.K. surgeons surveyed reported loss of surgical visualization at critical times during laparoscopic surgery, caused by the decrease in pneumoperitoneum during CO2 cylinder exchange. Eighty-four percent said that the process contributed to the surgeon's stress, and 63% said that a device that maintains uninterrupted pneumoperitoneum would reduce the risk of intraoperative complications. In our locale, a timed cylinder exchange was, on average, 30 times quicker with the novel dual valve than by conventional cylinder exchange (mean conventional exchange time, 61.3 ± 7.3 s vs. novel device, 2.0 ± 0.2 s; P ≤ .0001) and could be performed just as rapidly by staff unfamiliar with the device (2.2 ± 0.3 s vs. 1.9 ± 0.4 s P = .1945). We suggest that this simple, low-cost system could be developed for use in a clinical setting to enhance patient safety.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.