• Zhonghua Wai Ke Za Zhi · Jan 2011

    Clinical Trial

    [Effects of different reference point on intra-abdominal pressure measurement in critically ill patients: a clinical trial].

    • Tian Liu, Song-Qiao Liu, Ling Liu, Cong-Shan Yang, -Yi Yang, and Hai-Bo Qiu.
    • Department of Critical Care Medicine, Zhongda Hospital, Southeast University, Nanjing 210009, China.
    • Zhonghua Wai Ke Za Zhi. 2011 Jan 1;49(1):49-52.

    ObjectiveTo investigate the effects of different reference point on intra-abdominal pressure (IAP) measurement.MethodsNine critically ill patients with risk of intra-abdominal hypertension (IAH) were studied from July 2008 to June 2010, all of the patients were equipped with abdominal cavity drain and urinary drainage tube. By which IAP was measured using direct and indirect methods respectively. The symphysis pubis, phlebostatic axis and the midaxillary line at the level of the iliac crest were defined as reference points. According to the different reference point, three sets of IAP measurements were obtained in the supine position with each method and kept as IAP(S), IAP(P), IAP(I). Bland-Altman method analysis and Pearson's correlation were performed to evaluate the relationships between results from different reference points with direct and indirect methods. Paired t-test was performed to evaluate the differences among different reference points.ResultsSixty measurements of IAP(S), IAP(P) and IAP(I) were obtained. In direct measurement through abdominal cavity drain, IAP(I) (13.8 ± 3.9) mmHg (1 mmHg = 0.133 kPa) was significantly higher than IAP(P) (12.8 ± 3.6) mmHg and IAP(S) (9.1 ± 3.6) mmHg, P < 0.05; while in indirect measurement through urinary drainage tube, IAP(I) (12.7 ± 3.2) mmHg was significantly higher than IAP(P) (11.7 ± 2.9) mmHg and IAP(S) (7.9 ± 3.0) mmHg too, P < 0.05. In either direct or indirect method, IAP(P) was higher than IAP(S), P < 0.05. And good correlations were found among IAP(S), IAP(P) and IAP(I).ConclusionsIn the supine position, pressure obtained via the bladder could reflect authentic IAP. But selection of reference point has great impact on IAP measurement.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.