BackgroundConcomitant use of opioids and benzodiazepines can result in significant untoward effects. Point of care (POC) urine testing devices are commonly used tools to monitor patient use of medications. These useful devices are relatively inexpensive and yield immediate results that can be acted upon at the time of the appointment, although numerous limitations have been identified for specific medications or medication classes. We established the diagnostic accuracy of a commonly used POC testing method for benzodiazepines.MethodsOne thousand patients, from a single interventional pain practice receiving opioid therapy provided urine specimens as part of the usual practice of monitoring consistency with prescribed medications. These de-identified urine specimens were tested using LC-MS/MS and the results were compared using the standard calculations for sensitivity, specificity, and predicted value. Five specimens were excluded from the study because the prescribed flurazepam could not be confirmed by LC-MS/MS (the LC-MS/MS instrumentation was not set to identify flurazepam), resulting in 995 specimens.ResultsPoint of care assays yielded false negative results for patients prescribed benzodiazepines nearly 20% of the time (98 out of 498 patients). The point of care cup often failed to produce positive results for persons who were shown by LC-MS/MS to be taking lorazepam or clonazepam. Although only 26 out of 498 patients (5%) were prescribed ≥2 benzodiazepines, 73 out of 498 patients (15%) were found to be positive for that drug class.ConclusionsPOC immunoassay for benzodiazepines could fail to provide accurate information regarding patient specific medication use. The false positive and false negative rates of the immunoassay were particularly high for clonazepam and lorazepam. Further testing of patient specimens using more accurate methods such as LC-MS/MS is necessary to provide definitive data that can assist in clinical decision making, and potentially protect these patients from untoward effects, morbidity and mortality.Copyright © 2012 Elsevier B.V. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.