-
Comparative Study
Novel measurements of periaortic adipose tissue in comparison to anthropometric measures of obesity, and abdominal adipose tissue.
- C L Schlett, J M Massaro, S J Lehman, F Bamberg, C J O'Donnell, C S Fox, and U Hoffmann.
- Cardiac MR PET CT Program, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.
- Int J Obes (Lond). 2009 Feb 1;33(2):226-32.
BackgroundPerivascular adipose tissue may be associated with the amount of local atherosclerosis. We developed a novel and reproducible method to standardize volumetric quantification of periaortic adipose tissue by computed tomography (CT) and determined the association with anthropometric measures of obesity, and abdominal adipose tissue.MethodsMeasurements of adipose tissue were performed in a random subset of participants from the Framingham Heart Study (n=100) who underwent multidetector CT of the thorax (ECG triggering, 2.5 mm slice thickness) and the abdomen (helical CT acquisition, 2.5 mm slice thickness). Abdominal periaortic adipose tissue (AAT) was defined by a 5 mm cylindrical region of interest around the aortic wall; thoracic periaortic adipose tissue (TAT) was defined by anatomic landmarks. TAT and AAT were defined as any voxel between -195 and -45 HU and volumes were measured using dedicated semiautomatic software. Measurement reproducibility and association with anthropometric measures of obesity, and abdominal adipose tissue were determined.ResultsThe intra- and inter-observer reproducibility for both AAT and TAT was excellent (ICC: 0.97 and 0.97; 0.99 and 0.98, respectively). Similarly, the relative intra- and inter-observer difference was small for both AAT (-1.85+/-1.28% and 7.85+/-6.08%; respectively) and TAT (3.56+/-0.83% and -4.56+/-0.85%, respectively). Both AAT and TAT were highly correlated with visceral abdominal fat (r=0.65 and 0.77, P<0.0001 for both) and moderately correlated with subcutaneous abdominal fat (r=0.39 and 0.42, P<0.0001 and P=0.009), waist circumference (r=0.49 and 0.57, P<0.0001 for both) and body mass index (r=0.47 and 0.58, P<0.0001 for both).ConclusionStandardized semiautomatic CT-based volumetric quantification of periaortic adipose tissue is feasible and highly reproducible. Further investigation is warranted regarding associations of periaortic adipose tissue with other body fat deposits, cardiovascular risk factors and clinical outcomes.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.