- A Kamiya, K Yamakoshi, M Shibata, A Kawarada, and H Shimazu.
- Heart Vessels. 1986 Jan 1;2(2):91-101.
AbstractA theoretical analysis of the step response in the closed cardiovascular system induced by a sudden shift of the right cardiac output curve predicted that if the relations of the right heart output (COr) and the total systemic capillary flow (CFs) to the systemic venous pressure (Psv) are linear, then the time course of Psv change will become monoexponential with a time constant T given by T = Csv/(Gr + Gs), where Csv is the systemic vein compliance and Gr and Gs are the conductances of the transient COr-Psv and CFs-Psv relationships. A similar prediction was obtained for the time constant T of the pulmonary vein pressure (Ppv) response to the step change in the left cardiac output (COl) curve, pulmonary vein compliance (Cpv) and the conductances of the COl curve, and the pulmonary capillary flow (CFp) curve against Ppv. The actual Psv or Ppv changes following sudden alteration of the COr or COl curve by inflation and deflation of the balloon in the right or left atrium revealed monoexponential time courses. Semilogarithmic plots of the transient vein pressure changes yielded correlation coefficients of -0.995 +/- 0.006 (means +/- SD) in 11 curves for Psv and 0.977 +/- 0.017 in 16 curves for Ppv (P less than 0.01). The assumed linearity of dynamic COr and COl curves was confirmed by beat by beat COr-Psv and COl-Ppv relationships during the step responses, except for the first few beats immediately after the balloon maneuver. The linearity of the dynamic CFs curve was examined by measuring CFs with a double-step balloon maneuver so as to cause rapid equilibrium between COr and CFs at varied moments of the transient process. The correlation coefficient between CFs and Psv thus obtained was 0.98 +/- 0.04 (P less than 0.01). A similar linearity of the dynamic CFp-Ppv relationship was suggested from their steady-state curves. The values of Csv calculated from the experimental data were 1.70 +/- 0.12 ml/mmHg/kg body wt in 11 curves and those of Cpv were 0.13 +/- 0.03 ml/mmHg/kg in 15 curves. These results are mostly consistent with those previously reported.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.