Arch. Dis. Child. Fetal Neonatal Ed. · Sep 2010
Comparative StudyOxygen delivery using neonatal self-inflating resuscitation bags without a reservoir.
- M Thió, R Bhatia, J A Dawson, and P G Davis.
- Neonatal Service, University Hospital Sant Joan de Déu, Barcelona, Spain. mthio@hsjdbcn.org
- Arch. Dis. Child. Fetal Neonatal Ed. 2010 Sep 1;95(5):F315-9.
BackgroundGuidelines recommend avoidance of excessive oxygen administration during neonatal resuscitation. Blenders are used in some but not all hospitals. It has been suggested that self-inflating bags without a reservoir deliver around 40% oxygen and could be used to provide an inexpensive and effective technique of avoiding oxygen toxicity.ObjectiveTo explore how much oxygen is delivered when using two different brands of neonatal self-inflating resuscitation bags without a reservoir.MethodsIn a benchtop setting, the smallest non-disposable self-inflating bags from the Laerdal and Ambu ranges were tested. Oxygen concentration delivered by these devices under a variety of conditions was measured. 108 combinations of oxygen flow rates (10; 5 to 1 litre/min), ventilation rates (30, 60, 100 inflations/min) and peak inspiratory pressure ranges (20 to 25 cm H(2)O, 35 to 40 cm H(2)O or pop-off valve range, 55 to 60 cm H(2)O) were tested.ResultsDelivered oxygen concentration varied depending on three parameters: gas flow rate, ventilatory rate and pressure. At a pressure of 20 to 25 cm H(2)O, mean oxygen concentration delivered by both bags exceeded 70% at any gas flow rate except for 1 litre/min (where delivered oxygen concentration was 60% to 70%). When the pop-off valve was opened at 35 to 40 cm H(2)0, oxygen concentrations fell to 30% to 45% at gas flow rates < or =2 litres/min. The Ambu bag delivered a lower oxygen concentration than the Laerdal bag but this difference was not clinically important.ConclusionWhen using the Laerdal and Ambu infant resuscitation self-inflating bags without a reservoir, delivered oxygen concentration is >70% for currently recommended flow and pressure settings.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.