- C A Portera, R P Compton, D N Walters, and I W Browder.
- Department of Surgery, East Tennessee State University, Johnson City 37614-0575.
- Am. J. Surg. 1995 Feb 1;169(2):202-6; discussion 206-7.
BackgroundBecause the abdominal insufflation and desufflation associated with laparoscopic procedures may adversely effect a compromised myocardium, patients with significant cardiopulmonary disease should be closely monitored during these procedures. The utility of intraoperative pulmonary artery catheter (PAC) and transesophageal echocardiography (TEE) monitoring was studied in 10 patients with moderate to severe cardiopulmonary disease to identify patients at greatest risk for cardiovascular complications during laparoscopic cholecystectomy.MethodsTen patients were enrolled in this prospective study; 7 had suffered a previous myocardial infarction, 6 had undergone coronary artery bypass grafting, and 9 had disease classified as Goldman's class II or greater. The heart was monitored by TEE throughout the laparoscopic cholecystectomy by using real-time, two-dimensional mode to study the wall thickness and motion. Several PAC measurements were taken directly: cardiac output, systemic vascular resistance, pulmonary artery wedge pressure, and central venous pressure. Heart rate and blood pressure were also obtained at corresponding intervals. Cardiac index, stroke volume, and left and right ventricular stroke work were then calculated.ResultsTEE demonstrated no significant changes in ventricular wall motion throughout laparoscopy. In patients who had postoperative cardiovascular complications, significant changes in cardiac index, left ventricular stroke work, and stroke volume were seen after pneumoperitoneum release. Compared to that of patients who did not develop complications, the cardiac index in those with complications dropped 42% (3.10 +/- 0.72 versus 1.80 +/- 0.10 L/min per m2, respectively; P < 0.01); left ventricular stroke work dropped 64% (139.00 +/- 11.36 versus 50.38 +/- 10.55 g x min/beat, respectively; P < 0.01); and stroke volume dropped 51% (86.90 +/- 12.68 versus 42.50 +/- 5.08 mL/beat, respectively; P < 0.01).ConclusionsPCA monitoring in patients with compromised cardiac function is useful in identifying patients who may not tolerate hemodynamic changes after pneumoperitoneum release. Normalization of hemodynamic changes secondary to abdominal insufflation and desufflation in patients with compromised hearts may not occur in patients with compromised hearts may not occur for hours postoperatively. Abnormal hemodynamic changes occur within the first hour after desufflation in patients who later develop cardiovascular complications, which are heralded by significant drops in left ventricular stroke work, cardiac index, and stroke volume. TEE did not prove to be useful for intraoperative monitoring.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.