• Critical care medicine · Mar 1996

    Iced temperature injectate for thermodilution cardiac output determination causes minimal effects on cardiodynamics.

    • H K Fang, R L Krahmer, E B Rypins, and W R Law.
    • Department of Surgery, University of Illinois at Chicago, College of Medicine 60612, USA.
    • Crit. Care Med. 1996 Mar 1;24(3):495-500.

    ObjectivesControversy exists regarding the ideal injectate temperature for measuring cardiac output. Iced temperature injectate gives a higher signal/noise ratio and less variability in the measured cardiac output. Thus, less volume and fewer measurements are required. Advocates of room temperature injectate have suggested that iced temperature injectate may perturb cardiodynamics. This concern has remained largely untested. To help resolve this controversy, we examined the effects of 5 mL iced injectate (0 degrees to 4 degrees) infusions on cardiodynamics.DesignProspective, randomized, controlled study.SettingA critical care research laboratory.SubjectsFive domestic pigs, weighing between 20 to 25 kg.InterventionsUnder barbiturate anesthesia, pigs underwent placement of a) a thermodilution catheter in the right internal jugular vein; b) a right carotid artery catheter for mean arterial pressure; and c) sonomicrometry crystals for dynamic measurements of left ventricular dimensions. Calculations were made of end-systolic and end-diastolic left ventricular volume and ejection fraction. Six cardiac output measurements were performed in each pig. Data were obtained at baseline (just before iced temperature injectate infusion) and every 3 sec for 9 secs.Measurements And Main ResultsThe only significant effect seen with iced temperature injectate infusion was a small, transient decrease in heart rate (-5.9 +/- 1.1 beats/min from a baseline heart rate of 144.8 +/- 20.6 beats/min). Indices of preload, contractile function, and dynamic cardiac geometry were unaffected.ConclusionsIced temperature injectate used in clinically relevant volumes causes transient negative chronotropic effects, but reservations regarding other perturbations of cardiodynamics are unfounded. Thus, the use of iced temperature injectate for cardiac output determination is still a viable alternative to room temperature injectate use, especially when a larger signal/noise ratio is required.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.