• J Card Surg · May 1998

    Comparative Study

    Aortic pulmonary autograft implant: medium-term follow-up with a note on a new right ventricular pulmonary artery conduit.

    • P Masetti, G P Ussia, D Gazzolo, S M Marianeschi, R F Abella, A Cipriani, C Labia, F S Iorio, and C F Marcelletti.
    • The Department of Cardiac Surgery Hesperia Hospital, Modena, Italy.
    • J Card Surg. 1998 May 1;13(3):173-6.

    BackgroundThe Ross operation has been applied to various aortic valve pathologies, particularly when somatic growth is an issue. However, associated cardiac disease and technical problems may limit its use with regard to associated procedures and issues of right ventricular outflow reconstruction.Materials And MethodsFrom December 1992 to March 1998, 24 patients underwent aortic pulmonary autograft implantation. There were 14 males and 10 females, 15+/-10 years of age (mean +/- SD) (range 1 to 50 years), weighing 42.8+/-20 kg (mean +/- SD) (range 8 to 78 kg). Aortic insufficiency was present in 15 (62.5%) patients, stenosis in 8 (33.3%) patients, and valvar stenosis associated with left ventricular outflow tract obstruction in 1 (4.1%) patient. Etiology was rheumatic in 17 patients and congenital in 7. The Ross procedure was accompanied by a partial-Konno left ventricular outflow enlargement in one patient, and mitral valve annuloplasty, mitral commissurotomy, and tricuspid valve replacement in three other patients, respectively. The right ventricular outflow was reconstructed with a valved pulmonary homograft in 14 patients and with a Shelhigh No-React porcine pulmonary conduit in 10 patients. Evaluation was done by New York Heart Association (NYHA) Class and by echocardiography at a follow-up of 22.8+/-24 months (mean +/- SD) (range 3 to 63 months).ResultsThere were no operative mortalities and no postoperative arrhythmias. One (4.1%) patient required intra-aortic balloon pump (IABP) support for 3 days, one (4.1%) patient died 2 years later of probable arrhythmia, and one (4.1%) patient required mechanical aortic valve replacement 2 years later for severe autograft insufficiency. Left ventricular ejection fraction was unchanged (preoperative 62.4%+/-30%, postoperative 64.2%+/-30% [mean +/- SD], [p = NS]) and no significant gradient was documented by echocardiographic Doppler in the right and left ventricular outflow tracts. The aortic insufficiency scale decreased from a mean of 3.9+/-0.2 to a mean of 1+/-0 (p < 0.01). NYHA Class decreased to I in all patients, from III (10) and II (14).ConclusionsThe pulmonary autograft in the aortic position is suitable for aortic valve replacement in pediatric and adult patients with good medium-term results and in patients with rheumatic etiology, and it provides a desirable solution in the presence of associated pathologies, such as left ventricular tract obstruction or associated multivalvular disease. The development of new means of right ventricular outflow reconstruction must parallel the progress achieved for the left side.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.