• Journal of cardiology · May 2012

    Comparative Study

    Comparison of two-dimensional and real-time three-dimensional transesophageal echocardiography in the assessment of aortic valve area.

    • Atsuko Furukawa, Yukio Abe, Chiharu Tanaka, Kazato Ito, Isao Tabuchi, Kazuhiro Osawa, Naoto Kino, Eiichiro Nakagawa, Ryushi Komatsu, Kazuo Haze, Minoru Yoshiyama, Junichi Yoshikawa, Takahiko Naruko, and Akira Itoh.
    • Department of Cardiology, Osaka City General Hospital, Osaka, Japan.
    • J Cardiol. 2012 May 1;59(3):337-43.

    BackgroundThe accuracy of two-dimensional transesophageal echocardiography (2D-TEE) for the measurement of aortic valve area (AVA) in patients with aortic stenosis (AS) depends upon the cross-section selected for imaging. Real-time three-dimensional transesophageal echocardiography (3D-TEE) may overcome this limitation of 2D-TEE. The goal of this study was to compare 3D-TEE with 2D-TEE for the measurement of AVA.Methods And ResultsTwenty-five patients with AS underwent TEE. In 2D-TEE, the aortic valve image was obtained at the orifice level in the short-axis view, and AVA was measured by planimetry of the acquired images (2D-AVA). In 3D-TEE, 3D data containing the entire aortic valve were obtained. Then, a short-axis cross-section containing the smallest orifice in mid-systole was cut from the 3D data during image postprocessing, and the AVA was measured by planimetry (3D-AVA). The 3D-AVA was significantly smaller than the 2D-AVA (0.79±0.35cm(2) vs. 0.93±0.40cm(2), p<0.0001), but there was a strong correlation between 3D-AVA and 2D-AVA (R=0.94). Although the frame rate was lower in 3D-TEE than in 2D-TEE (17±6Hz vs. 58±16Hz), the 3D-AVA determined at each frame during systole showed that the difference between 3D-AVA and 2D-AVA was not explained by the lower frame rate. The time required for image acquisition of the aortic valve was shorter with 3D-TEE than with 2D-TEE (p=0.0005).ConclusionsThe geometric AVA is smaller with 3D-TEE than with 2D-TEE, and the difference is not due to the lower frame rate of 3D-TEE. The improved accuracy of 3D-TEE along with reduced image acquisition time indicates that 3D-TEE is superior to 2D-TEE for the assessment of AVA.Copyright © 2012 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…