Klin Monbl Augenheilkd · Jan 2001
[Automated swinging flashlight test in patients with optic nerve diseases].
- B Wilhelm, H Lüdtke, T Peters, R Schmid, H Wilhelm, and E Zrenner.
- Steinbeis-Transferzentrum für Biomedizinische Optik und Funktionsprüfung Tübingen, Röntgenweg 11, 72076 Tübingen. barbara.wilhelm@uni-tuebingen.de
- Klin Monbl Augenheilkd. 2001 Jan 1;218(1):21-5.
Aim Of The StudyThe swinging flashlight test is an objective method to diagnose a lesion of the anterior visual pathways. However, errors and faults may easily alter the test's results. Hence, the value of the swinging flashlight test depends highly on the examiner's skills. Therefore an automated and objective procedure was developed which is independent from the examiner.MethodsA binocularly measuring instrument adapted for video pupillography was supplied with two arrays of light emitting diodes in front of each eye of the subject. By means of this illumination, pupillary light reflexes are elicited alternately. Pupil size is registered continuously, and after artifact elimination, the response amplitudes of the pupils are determined as a mean of right and left pupil. Responses elicited via right and left eye are compared. By varying the stimulus intensity it is possible to measure the amount of the relative afferent pupillary defect. The procedure was tested in 31 patients with optic nerve disorders.ResultsThe measurements were easily feasible, stable and reliable. Correlation between the relative afferent pupillary defect detected manually by grey filter compensating and with the automated procedure proved to be high. Both variables correlated highly significant with a Spearman rank coefficient of 0.65. If the clinical test is regarded as the golden standard, the automated swinging flashlight test is able to detect 85% of the relative afferent pupillary defects > or = 0.3 logE and 94% of the defects > or = 0.6 logE.ConclusionThe automated swinging flashlight test can be recommended to exclude influences by the examiner or if the exact amount of the relative afferent pupillary defect is desired, e.g. when monitoring therapeutic effects in optic nerve diseases. Furthermore, an automated swinging flashlight test could serve as a screening test.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.