• Anesthesia and analgesia · Nov 1998

    Randomized Controlled Trial Comparative Study Clinical Trial

    A comparison of the reliability of two techniques of left double-lumen tube bronchial cuff inflation in producing water-tight seal of the left mainstem bronchus.

    • M S Hannallah, F Gharagozloo, M N Gomes, and G A Chase.
    • Department of Anesthesiology, Georgetown University Medical Center, Washington, District of Columbia 20007, USA.
    • Anesth. Analg. 1998 Nov 1;87(5):1027-31.

    UnlabelledA double-lumen endobronchial tube (DLT) bronchial cuff inflation technique that reliably ensures effective water-tight isolation of the two lungs has not been determined. In this study, 20 patients undergoing thoracic surgery requiring a left DLT had the bronchial cuff of the DLT inflated by one of two techniques. In Group 1, the cuff was inflated to produce an air-tight seal of the left bronchus using the underwater seal technique. In Group 2, the cuff was inflated to a pressure of 25 cm H2O. After bronchial cuff inflation in both groups, water-tight bronchial seal was tested by instilling 2 mL of 0.01% methylene blue (MB) above the bronchial cuff of the DLT. Fifteen minutes later, fiberoptic bronchoscopy was performed via the bronchial lumen of the DLT to determine whether MB had seeped past the bronchial cuff. Cuff volume was 0.75+/-0.64 and 0.76+/-0.46 mL, cuff pressure was 30.1+/-27.0 and 25.0+/-0.0 cm H2O (mean+/-SD), and MB was positively identified in two and five patients in Groups 1 and 2, respectively. The difference in cuff volume and pressure and the higher MB seepage in Group 2 compared with Group 1 was not statistically significant. In both groups, MB seepage occurred only when the bronchial cuff volume was <1 mL and when the patients were positioned in the left lateral decubitus position. These findings suggest that the risk of aspiration is greatest when the DLT is positioned in the dependent lung and when the bronchial cuff volume is <1 mL.ImplicationsWater-tight sealing of the left bronchus by DLT bronchial cuff was tested after cuff inflation using two different techniques. Neither air-tight bronchial seal nor cuff pressure of 25 cm H2O guaranteed protection against aspiration. The risk of aspiration was greatest when the DLT was positioned in the dependent lung and when the bronchial cuff volume was < 1 mL.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.