    Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform.

    • R Pizov, M Cohen, Y Weiss, E Segal, S Cotev, and A Perel.
    • Department of Anesthesiology and Critical Care Medicine, Hadassah University Hospital, Jerusalem, Israel.
    • Crit. Care Med. 1996 Aug 1;24(8):1381-7.

    ObjectiveTo examine whether the hemodynamic changes due to mechanical ventilation with positive end-expiratory pressure (PEEP) can be assessed by the respiratory-induced variations in the arterial pressure waveform during normovolemia and experimental acute ventricular failure.DesignProspective, controlled experimental study.SettingInstitutional experimental laboratory.SubjectsAdult mongrel dogs.InterventionsExperimental acute ventricular failure was induced by the infusion of pentobarbital (a cardiodepressant) and methoxamine (a vasoconstrictor), combined with volume loading. Both the control and acute ventricular failure groups were subjected to ventilation with incremental levels of PEEP up to 20 cm H2O.Measurements And Main ResultsCardiac function was evaluated by cardiac output and left and right ventricular change in pressure over time (dP/dt) measurements. Arterial pressure waveform analysis was performed by measuring the systolic pressure variation, which is the difference between the maximal and minimal systolic blood pressure values during one mechanical breath. The components of the systolic pressure variation, namely, dUp and dDown, which are the increase and decrease in the systolic pressure during the mechanical breath relative to the systolic pressure during apnea, were also measured at each PEEP level. PEEP caused significant reduction of cardiac output in normovolemic dogs, and was associated with significant increases in systolic pressure variation and dDown. Acute ventricular failure decreased the variations in the systolic pressure and caused the dDown component to disappear. The application of PEEP did not affect cardiac output in dogs with acute ventricular failure, nor did it change systolic pressure variation and the dDown.ConclusionsAnalysis of arterial pressure waveforms during mechanical ventilation reflected the decrease in cardiac output in dogs with normal cardiac function subjected to incremental PEEP. In dogs with acute ventricular failure in which PEEP did not affect cardiac output, the systolic pressure variation was similarly unaffected by PEEP. In the absence of cardiac output measurement during mechanical ventilation with PEEP, the analysis of the respiratory variations in the arterial pressure waveform may be useful in assessing changes in cardiac output.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.