J. Am. Coll. Cardiol. · Sep 2014
Randomized Controlled Trial Multicenter Study Comparative StudyAssociation between frequency of atrial and ventricular ectopic beats and biventricular pacing percentage and outcomes in patients with cardiac resynchronization therapy.
- Martin H Ruwald, Suneet Mittal, Anne-Christine Ruwald, Mehmet K Aktas, James P Daubert, Scott McNitt, Amin Al-Ahmad, Christian Jons, Valentina Kutyifa, Jonathan S Steinberg, Paul Wang, Arthur J Moss, and Wojciech Zareba.
- Heart Research Follow-up Program, University of Rochester Medical Center, Rochester, New York; Department of Cardiology, Gentofte Hospital, Hellerup, Denmark. Electronic address: mruwald@hotmail.com.
- J. Am. Coll. Cardiol. 2014 Sep 9;64(10):971-81.
BackgroundA high percentage of biventricular pacing is required for optimal outcome in patients treated with cardiac resynchronization therapy (CRT), but the influence of ectopic beats on the success of biventricular pacing has not been well established.ObjectivesThis study sought to determine if increased ectopic beats reduce the chance of high biventricular pacing percentage and are associated with subsequent adverse outcomes.MethodsFrom the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy), 801 patients with an implanted CRT-defibrillator device with data available on biventricular pacing percentage and pre-implantation 24-h Holter recordings were included. Using logistic regression, we estimated the influence of ectopic beats on the percentage of biventricular pacing. Reverse remodeling was measured as reductions in atrial and left ventricular end-systolic volumes (LVESV) at 1 year. Cox models were used to assess the influence of ectopic beats on the outcomes of heart failure (HF) or death, ventricular tachyarrhythmias (VTAs), and death.ResultsIn the pre-implantation Holter recording, ectopic beats accounted for a mean 3.2 ± 5.5% of all beats. The probability of subsequent low biventricular pacing percentage (<97%) was increased 3-fold (odds ratio: 3.37; 95% confidence interval: 1.74 to 6.50; p < 0.001) in patients with 0.1% to 1.5% ectopic beats and 13-fold (odds ratio: 13.42; 95% confidence interval: 7.02 to 25.66; p < 0.001) in patients with >1.5% ectopic beats compared with those with <0.1% ectopic beats. Patients with ≥0.1% ectopic beats had significantly less reverse remodeling (percent reduction in LVESV 31 ± 15%) than patients with <0.1% ectopic beats (percent reduction in LVESV 39 ± 14%; p < 0.001). The risk of HF/death and VTA was increased significantly in those with 0.1% to 1.5% ectopic beats (hazard ratio: 3.13 and 1.84, respectively) and for >1.5% ectopic beats (hazard ratio: 2.38 and 2.74, respectively).ConclusionsRelatively low frequencies of ectopic beats (≥0.1%) dramatically increase the probability of low biventricular pacing (<97%), with reduced CRT efficacy by less reverse remodeling and higher risk of HF/death and VTA. This supports pre-implantation Holter monitoring of patients selected for CRT for optimal outcome. (MADIT-CRT: Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy; NCT00180271).Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.