-
- Jonathan O Swanson, Adam M Alessio, Klane K White, Walter F Krengel, Seth D Friedman, Neil C Vining, and Kit M Song.
- *Department of Radiology, Seattle Children's Hospital and University of Washington, Seattle, WA†Department of Radiology, University of Washington, Seattle, WA‡Department of Orthopedics, Seattle Children's Hospital, University of Washington, Seattle, WA§Department of Radiology, Seattle Children's Hospital, Seattle, WA¶Raleigh Orthopaedic Clinic, Raleigh, NC; and∥Department of Orthopaedic Surgery, Shriners Hospitals for Children, Los Angeles, CA.
- Spine. 2015 Oct 15; 40 (20): 1613-9.
Study DesignRetrospective dose-simulation comparison.ObjectiveTo determine if sufficient detail for preoperative analysis of bony anatomy can be acquired at substantially lower doses than those typically used.Summary Of Background DataComputed tomography (CT) is a preoperative planning tool for spinal surgery. The pediatric population is at risk to express the harmful effects of ionizing radiation. Preoperative CT scans are presently performed at standard pediatric radiation doses not tailored for surgical planning.MethodsWe used the validated GE Noise Injection software to retrospectively modify existing spine and chest CT scans from 10 patients to create CT images that simulated a standard dose (100%), 50% dose, and 25% dose scans. 4 orthopedic surgeons and a pediatric radiologist, blinded to dose, measured minimum medial-lateral pedicle width and maximum anterior-posterior bony length along the axis of presumed pedicle screw placement. A total of 90 axial images were generated to create our sample set. Measurements were evaluated for accuracy, precision, and consistency.ResultsFor any given rater, there was no clinically relevant difference between measurements at the different dose levels and no apparent degradation in precision at the different dose levels. Consistent variation was observed between raters, the likely result of individual differences in measurement approach.ConclusionSpinal CT scans done for preoperative planning can be performed at 25% of current radiation doses without a loss in surgical planning measurement accuracy or precision. These 25% dose-reduced scans would have average Computed Tomography Dose Index volume dose levels of roughly 1.0 to 2.5 mGy (depending on patient size) and size-specific dose estimates of roughly 2.5 mGy representing a substantial dose savings compared to current practice for many sites. Standardization of consistent landmarks may be useful to further improve inter-rater concordance.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.