• Acta Chir Orthop Traumatol Cech · Jan 2011

    Comparative Study

    Biomechanical comparison of an interspinous device and a rigid stabilization on lumbar adjacent segment range of motion.

    • F Hartmann, S O Dietz, S Kuhn, H Hely, P M Rommens, and E Gercek.
    • Department of Trauma Surgery, University Medical Centre, Mainz, Germany.
    • Acta Chir Orthop Traumatol Cech. 2011 Jan 1;78(5):404-9.

    Purpose Of The StudyDecompression surgery with or without fusion is the gold standard treatment of lumbar spinal stenosis, but adjacent segment degeneration has been reported as a long-term complication after fusion. This led to the development of dynamic implants like the interspinous devices. They are supposed to limit extension and expand the spinal canal at the symptomatic level, but with reduced effect on the range of motion of the adjacent segments. The aim of the present study is the evaluation of the biomechanical effects on the range of motion (ROM) of adjacent lumbar segments after decompression and instrumentation with an interspinous device compared to a rigid posterior stabilization device.Materials And MethodsEight fresh frozen human cadaver lumbar spines (L2-L5) were tested in a spinal testing device with a moment of 7.5 Nm in flexion/extension, lateral bending and rotation with and without a preload. The preload was applied as a follower load of 400N along the curvature of the spine. The range of motion (ROM) of the adjacent segments L2/L3 and L4/L5 was measured with the intact segment L3/L4, after decompression, consisting of resection of the interspinous ligament, flavectomy and bilateral medial facetecomy, and insertion of the Coflex® (Paradigm Spine, Wurmlingen) and after instrumentation with Click X® (Synthes, Umkirch) as well.ResultsThe interspinous and the rigid device caused a significant increase of ROM at both adjacent segments during all directions of motion and under follower load, without significant difference between these devices. The ROM of L2/L3 tends to increase more than the ROM of L4/L5 after instrumentation without statistical significance.DiscussionThe "dynamic" Coflex device caused a significant increase of ROM at both adjacent lumbar segments comparable to the increase of ROM after instrumentation with the rigid Click X device. Other in vitro studies observed comparable biomechanical effects on the adjacent segments after fusion, but biomechanical spacer studies concentrated on the "noncompressible" X-Stop® and could not demonstrate a significant adjacent segment effect of this device.ConclusionsThe hypothesis, that an interspinous device would reduce the stress on adjacent segments compared to a rigid posterior stabilization device, could not be demonstrated with this biomechanical in vitro study. Therefore, the protection of adjacent segments after instrumentation with dynamic devices is still not completely achieved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.