• J Bone Joint Surg Am · Mar 2008

    Results of polyaxial locked-plate fixation of periarticular fractures of the knee. Surgical technique.

    • George Haidukewych, Stephen A Sems, David Huebner, Daniel Horwitz, and Bruce Levy.
    • Orthopedic Trauma Service, Florida Orthopedic Institute, 13020 Telecom Parkway, Temple Terrace, FL 33637, USA. docgjh@aol.com
    • J Bone Joint Surg Am. 2008 Mar 1;90 Suppl 2 Pt 1:117-34.

    BackgroundLocked-plate fracture-fixation techniques and designs continue to evolve. Polyaxial locking plates that allow screw angulation and end-point locking have become available; however, there are no clinical data documenting their strength and efficacy, to our knowledge. The purpose of this study was to evaluate the clinical performance of a variable-axis locking plate in a multicenter series of periarticular fractures about the knee.MethodsBetween 2003 and 2005, fifty-four patients with a total of fifty-six fractures were treated with a polyaxial locked-plate fixation system (DePuy, Warsaw, Indiana). There were twenty male patients and thirty-four female patients with a mean age of fifty-seven years. There were twenty-five distal femoral fractures and thirty-one proximal tibial fractures. Twelve of the fractures were open. Clinical and radiographic data, including changes in alignment, hardware breakage, or other mechanical complications of the device, were retrospectively reviewed. Function was assessed with use of the Knee Society scores. One patient with a bilateral fracture died less than three months postoperatively, and two patients were lost to follow-up prior to union. Fifty-two fractures in fifty-one patients were followed to union or for a minimum of six months; the mean duration of follow-up was nine months (range, six to twenty-five months).ResultsForty-nine (94%) of the fifty-two fractures united. There were no mechanical complications. Most importantly, there was no evidence of varus collapse as a result of polyaxial screw failure. There were three deep infections and one aseptic nonunion. No plate fractured, and no screw cut out.ConclusionsThe variable-axis locking plates performed well, with a high rate of fracture union and no evidence of varus collapse due to failure of the polyaxial screw fixation, in a series of complex fractures about the knee. Complication rates were similar to those for historical controls treated with fixed-trajectory locking plates. Polyaxial locking plates offer more fixation versatility without an apparent increase in mechanical complications or loss of reduction.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…