• Acta Anaesthesiol. Sin. · Sep 2002

    Randomized Controlled Trial Clinical Trial

    Cardiac output measurement during cardiac surgery: esophageal Doppler versus pulmonary artery catheter.

    • Nuan-Yen Su, Chun-Jen Huang, Peishan Tsai, Yung-Wei Hsu, Yu-Chun Hung, and Ching-Rong Cheng.
    • Department of Anesthesiology, Mackay Memorial Hospital, 92 Sec. 2 Chung San N. Road, Taipei 10449, Taiwan, R.O.C.
    • Acta Anaesthesiol. Sin. 2002 Sep 1;40(3):127-33.

    BackgroundBolus thermodilution cardiac output (BCO) measurement has been considered as the "gold standard" for cardiac output (CO) measurement. However, it requires placement of a pulmonary artery (PA) catheter, and questions have been raised regarding the risk/benefit ratio of this invasive technique. Furthermore, great variations between measurements have been reported. Continuous thermodilution CO (CCO) measurement is reported to be a better alternative, but it still requires the placement of a PA catheter. Esophageal echo-Doppler ultrasonography (ED) provides non-invasive continuous measurement of CO (ED-CO). This study was thus designed to compare the agreement between ED-CO and both thermodilution techniques (BCO and CCO).MethodsTwenty-four patients undergoing primary coronary artery bypass graft surgery were randomized to have a PA catheter placed for measurement of either BCO or CCO. All patients also had an ED probe placed. In Group I patients (n = 12), BCO measurement was carried out every 15 minutes throughout the surgery except during cardiopulmonary bypass, with concurrent ED-CO reading recorded at the same time point. In Group II patients (n = 12), CCO and ED-CO measurements were recorded at the same designated points of time as in Group I. The agreement between methods (BCO vs. ED-CO or CCO vs. ED-CO) was assessed using Bland-Altman method.ResultsThe range of measured CO of each method was 2.1 to 9.4 l/min for BCO, 2.4 to 9.2 l/min for CCO and 2.3 to 8.9 l/min for ED-CO. ED-CO and CCO had excellent agreement with a linear regression coefficient (r2 value) of 0.846, and a bias (mean difference) and SD of bias of 0.05 +/- 0.49 l/min. In contrast, the agreement between BCO and ED-CO was poorer; correlation was low (r2 value 0.406) and both the bias and SD of bias were high (0.11 +/- 1.12 l/min). Furthermore, BCO measurements had poor reproducibility, whereas both ED-CO and CCO measurements had good reproducibility.ConclusionsEsophageal echo-Doppler ultrasonography is a satisfactory alternative for cardiac output measurement because it gives a value in good agreement with CCO measurement. With significant between-measurement variations, the accuracy and precision of BCO are uncertain, and it should not be considered as the "gold standard".

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.